Standing versus supine radiographs in RSA evaluation of femoral head penetration

Bragdon, Charles R, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Thanner, Jonas, 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Greene, M. E. (författare)
visa fler...
Malchau, Henrik, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Digas, Georgios, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Harris, W. H. (författare)
Kärrholm, Johan, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2006
2006
Engelska.
Ingår i: Clin Orthop Relat Res. - 0009-921X. ; 448, s. 46-51
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Evaluation of polyethylene acetabular component wear in total hip arthroplasties commonly is performed using serial radiographs of the hip by measuring the change in the location of the center of the femoral head in relation to the acetabular component. Of the different methods currently used for this purpose, radiostereometric analysis (RSA) is considered the most accurate and precise. In all such radiographic studies, it is assumed the femoral head is seated into the deepest portion of the acetabular component during all radiographic examinations. Although most radiographs used for wear measurements are taken with the patient supine, we questioned whether standing radiographs, with substantial joint load, are better suited for these measurements. We evaluated two groups of patients having total hip arthroplasty who had radiostereometric radiographs taken in supine and standing positions. The average femoral head penetration that occurred between the 6-month and 2-year time interval was measured with radiographs taken in the standing or supine position. We found no difference between the average total femoral head penetration when using supine or standing radiographs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Arthrography/*methods
Arthroplasty
Replacement
Hip/*methods
Femur Head/*radiography/surgery
Follow-Up Studies
Hip Joint/*radiography/surgery
Humans
*Photogrammetry
*Posture
Prosthesis Failure
Time Factors

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy