SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Digas Georgios 1963)
 

Sökning: WFRF:(Digas Georgios 1963) > Influence of design...

Influence of design variations on early migration of a cemented stem in THA

Olofsson, Kent, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Digas, Georgios, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Kärrholm, Johan, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
 (creator_code:org_t)
2006
2006
Engelska.
Ingår i: Clin Orthop Relat Res. - 0009-921X. ; 448, s. 67-72
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The clinical results of using different cemented stems in total hip arthroplasty may vary because of shape, surface finish, and choice of metal alloy. Less is known about the influence of size and offset using one and the same design. Data from 140 patients (140 hips) of a cohort constituting 197 patients (231 hips) implanted with cemented Spectron Primary stems were extracted from patients studied in four randomized studies primarily designed for other purposes. Stem size (1, 2, 3, or larger), normal/extra offset, neck length and true offset (horizontal length between the stem and head center of the inserted modular implant) were recorded in millimeters. The radiographic appearance of the cementing was graded on the immediate postoperative radiograph according to Barrack. The patients were examined with radiostereometric analysis of stem migration for a 2-year followup period. Stem Size 1 (the smallest) showed an insignificant increase in subsidence compared with the bigger sizes. Using stepwise linear regression analysis, the quality of the cementing (Barrack C2) was the only parameter that had any certain influence of the subsidence at 2 years. Stem size 2 tended to show minimum valgus alignment and sizes 1 and 3 and bigger showed minimum varus tilting. Our findings suggest that placement of the stem with the tip against the posterior cortex (C2) and stem size influence the primary fixation in different ways. This effect is small, however, indicating that further confirmation with longer followup is necessary. LEVEL OF EVIDENCE: Therapeutic Level II-1 (prospective cohort study). See the Guidelines for Authors for a complete description of levels of evidence.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Adult
Aged
Aged
80 and over
Arthroplasty
Replacement
Hip/*instrumentation
Female
Follow-Up Studies
Foreign-Body Migration/complications/*prevention & control
*Hip Prosthesis
Humans
Joint Instability/etiology/prevention & control
Male
Middle Aged
Prognosis
Prospective Studies
Prosthesis Design
Prosthesis Failure

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Olofsson, Kent, ...
Digas, Georgios, ...
Kärrholm, Johan, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Clin Orthop Rela ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy