SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Karlsson Jón)
 

Search: WFRF:(Karlsson Jón) > (2005-2009) > The reliability of ...

The reliability of isokinetic testing of the ankle joint and a heel-raise test for endurance

Möller, Michael, 1957 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
Lind, Karin (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
Styf, Jorma, 1948 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
show more...
Karlsson, Jón, 1953 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
show less...
 (creator_code:org_t)
2005
2005
English.
In: Knee Surg Sports Traumatol Arthrosc. - 0942-2056. ; 13:1, s. 60-71
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The aim of the present study was to investigate the reliability of different methods used for isokinetic testing of calf muscle strength and endurance. The detailed evaluation of test-retest reliability serves the purpose of establishing reliable research tools when evaluating patients who have sustained an Achilles tendon rupture. The test-retest reliability of isokinetic measurements at the ankle for eccentric and concentric muscle action was calculated in ten healthy male volunteers using intra-class correlation (ICC) and coefficient of variation (CV). Three different positions were compared at the angular velocities of 30 degrees /s and 180 degrees /s for right and left ankles. The ICC for plantar flexion was 0.37-0.95, whilst it was 0.00-0.96 for dorsiflexion. The corresponding CVs were 4.0-19.9 and 2.4-19.8 respectively. The test-retest reliability of standardised heel-raises, Achilles tendon width, calf circumference and ankle range of motion revealed ICC values of 0.71-0.98 and CVs of 0.67-19.1. The test-retest interval was 5 to 7 days. We conclude that all three positions studied for the isokinetic evaluation of calf muscle function are equally reliable concerning plantar flexion at the ankle joint. The same level of reliability was also found in the evaluation of the standing heel-raise test and the isokinetic dorsiflexion test, except for dorsiflexion in the supine position. The reliability of the investigated methods was only fair despite the use of a detailed and standardised test protocol.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Achilles Tendon/physiology
Adult
Ankle Injuries/diagnosis
Ankle Joint/*physiology
Biomechanics
Humans
Male
Muscle Contraction/*physiology
Muscle
Skeletal/*physiology
Physical Endurance/*physiology
Posture/physiology
Reproducibility of Results
Torque

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Möller, Michael, ...
Lind, Karin
Styf, Jorma, 194 ...
Karlsson, Jón, 1 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
Knee Surg Sports ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view