SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Abrahamsson Hasse 1943)
 

Sökning: WFRF:(Abrahamsson Hasse 1943) > Percutaneous implan...

Percutaneous implantation of gastric electrodes - a novel technique applied in animals and in patients

Elfvin, Anders, 1971 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Andersson, S. (författare)
Abrahamsson, Hasse, 1943 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin,Institute of Medicine, Department of Internal Medicine
visa fler...
Edebo, Anders, 1968 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Simrén, Magnus, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin,Institute of Medicine, Department of Internal Medicine
Lönroth, Hans, 1952 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2007
2007
Engelska.
Ingår i: Neurogastroenterology and motility. - 1350-1925. ; 19:2, s. 103-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Temporary electrodes implanted under general anaesthesia, or via an oral or percutaneous endoscopic gastrostomy route have been used for testing of gastric electrical stimulation (GES). We have developed a principle for percutaneous electrode implantation. Leads were constructed so that the tip could be anchored to the gastric submucosa under gastroscopic control. Acute experiments were performed in anaesthetized pigs. Three patients referred for nausea and/or vomiting and non-established indications for GES (chronic intestinal pseudo-obstruction, functional dyspepsia without gastroparesis) were evaluated. Electrode function was tested by recording and stimulation techniques. In the pigs, a slow-wave (SW) rhythm (3 min(-1)) was recorded with decrease in frequency at the end of the experiments. In the patients, implantation time from start of gastroscopy to end of electrode placement was 12-20 min. Electrode distance varied from 12 to 45 mm. Gastric electromyography showed a regular SW rhythm of about 3 min(-1). Antral pressure waves had intervals being multiples of the SW-to-SW time. With temporary GES for 7-9 days, weekly frequency of the referral symptoms decreased >80% in two patients and 33% in one patient. Temporary percutaneous gastric leads can easily be implanted and may be used for testing of GES and study of gastric electrophysiology.

Nyckelord

Aged
80 and over
Animals
Dyspepsia/diagnosis/physiopathology
Electric Stimulation/instrumentation/*methods
*Electrodes
Implanted
Electromyography/instrumentation/*methods
Female
Gastric Emptying/physiology
Gastroscopy
Humans
Intestinal Pseudo-Obstruction/diagnosis/*physiopathology
Male
Manometry
Middle Aged
Stomach/*physiology
Swine
Vomiting/diagnosis/physiopathology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy