Femoral alignment of the Charnley stem: a randomized trial comparing the original with the new instrumentation in 123 hips.

Östgaard, Hans-Christian, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
Helger, Lilliane, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
Regnér, Hans, 1923 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
visa fler...
Garellick, Göran, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
visa färre...
 (creator_code:org_t)
2009-07-08
2001
Engelska.
Ingår i: Acta orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 72:3, s. 228-32
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Deficient cement mantles are associated with aseptic loosening of the stem component of total hip replacement. In a former study of 206 Charnley stems, we found high frequencies of stem malalignment, especially on the lateral view, consequently resulting in a high percentage of low cement mantle grading. If the "true" lateral radiographic projection is not used, there is a risk that the frequency of mantle defects is underestimated. A logistic regression analysis showed a high correlation between low cement mantle grading and stem loosening after a mean follow-up of 10 years. The new Charnley instrumentation was introduced in 1994 and we started a randomized trial including 123 prostheses to determine whether the new instrumentation improved the position of the stem in both the AP and lateral planes. Postoperative radiographs revealed a significant change in AP positioning-i.e., from a high percentage of varus with the original method to valgus with the new instrumentation. However, there was no difference on the lateral view, with a persisting high frequency of stems with implant-inner cortex contact resulting in high percentages of low cement-mantle grading in both systems. If this deficiency, in a long-term perspective, is associated with aseptic loosening, as many authors have claimed, the manufacturers should address the problem.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Aged
Aged
80 and over
Arthroplasty
Replacement
Hip
instrumentation
Female
Follow-Up Studies
Hip
radiography
Humans
Male
Middle Aged
Postoperative Complications
Regression Analysis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy