A new biomechanical perfusion system for ex vivo study of small biological intact vessels

Bergh, Niklas, 1979 (författare)
Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
Ekman, Mikael, 1960 (författare)
Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
Ulfhammer, Erik, 1974 (författare)
Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
visa fler...
Andersson, Maria, 1975 (författare)
Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
Karlsson, Lena, 1964 (författare)
Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
Jern, Sverker, 1954 (författare)
Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
visa färre...
 (creator_code:org_t)
Springer Science and Business Media LLC, 2005
2005
Engelska.
Ingår i: Ann Biomed Eng. - : Springer Science and Business Media LLC. - 0090-6964. ; 33:12, s. 1808-18
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The vascular endothelium transduces physical stimuli within the circulation into physiological responses, which influence vascular remodelling and tissue homeostasis. Therefore, a new computerized biomechanical ex vivo perfusion system was developed, in which small intact vessels can be perfused under well-defined biomechanical forces. The system enables monitoring and regulation of vessel lumen diameter, shear stress, mean pressure, variable pulsatile pressure and flow profile, and diastolic reversal flow. Vessel lumen measuring technique is based on detection of the amount of flourescein over a vessel segment. A combination of flow resistances, on/off switches, and capacitances creates a wide range of pulsatile pressures and flow profiles. Accuracy of the diameter measurement was evaluated. The diameters of umbilical arteries were measured and compared with direct ultrasonographic measurement of the vessel diameter. As part of the validation the pulsatile pressure waveform was altered, e.g., in terms of pulse pressure, frequency, diastolic shape, and diastolic reversal flow. In a series of simulation experiments, the hemodynamic homeostasis functions of the system were successfully challenged by generating a wide range of vascular diameters in artificial and intact human vessels. We conclude that the system presented may serve as a methodological and technical platform when performing advanced hemodynamic stimulation protocols.

Nyckelord

Animals
Blood Vessels/anatomy & histology/*physiology
*Diagnostic Imaging/instrumentation/methods
Endothelium
Vascular/*physiology
Homeostasis/*physiology
Humans
Mechanotransduction
Cellular/*physiology
Organ Culture Techniques
*Perfusion/instrumentation/methods

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy