SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:gup.ub.gu.se/57208"
 

Search: id:"swepub:oai:gup.ub.gu.se/57208" > Three-year folow-up...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Sundelin, KarinGothenburg University,Göteborgs universitet,Institutionen för klinisk neurovetenskap, Sektionen för oftalmologi,Institute of Clinical Neurosciences, Section of Ophtalmology (author)

Three-year folow-up of posterior capsule opacification with two different silicone intraocular lenses.

  • Article/chapterEnglish2005

Publisher, publication year, extent ...

  • 2005

Numbers

  • LIBRIS-ID:oai:gup.ub.gu.se/57208
  • https://gup.ub.gu.se/publication/57208URI

Supplementary language notes

  • Language:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • ABSTRACT. Purpose: To compare posterior capsule opacification (PCO) after cataract surgery with implantation of two silicone intraocular lenses (IOLs) with different designs. Methods: We carried out a prospective, clinical study of 116 patients randomized to standardized phacoemulsification with implantation of CeeOn Edge (n = 57) or SI40NB (n = 59) IOLs. The follow-up period was 3 years. To evaluate PCO morphologically, digital images were obtained and analysed using evaluation of posterior capsule opacification computer software (EPCO). The neodymium: YAG (Nd:YAG) capsulotomy rate was recorded. Results: At 2 and 3 years, the eyes with SI40NB IOLs had significantly more PCO than those with the CeeOn Edge IOLs (p = 0.00014 and p = 0.002). Nine Nd:YAG capsulotomies were performed in the SI40NB group and none in the CeeOn Edge group. This difference was statistically significant (p = 0.003). In some patients a regression of PCO was noticed and confirmed using EPCO. Statistically less PCO was noted when the capsulorhexis rim was placed so that it covered all 360 degrees of the optic of the IOL. Conclusions: A clinically and statistically significant difference in PCO development between CeeOn Edge and SI40NB IOLs at 2 and 3 years postoperatively was found. These findings support earlier studies indicating that a sharp edge of the optic is a more important factor in IOL design than IOL material in the prevention of PCO. Key words: posterior capsule opacification (PCO) – silicone – intraocular lens (IOL) – longterm follow-up – prospective – evaluation of posterior capsule opacification (EPCO) – capsulotomy – optic edge – regression

Subject headings and genre

  • posterior capsule opacification (PCO) – silicone – intraocular lens (IOL) – longterm

Added entries (persons, corporate bodies, meetings, titles ...)

  • Shams, H (author)
  • Stenevi, Ulf,1943Gothenburg University,Göteborgs universitet,Institutionen för klinisk neurovetenskap, Sektionen för oftalmologi,Institute of Clinical Neurosciences, Section of Ophtalmology(Swepub:gu)xsteul (author)
  • Göteborgs universitetInstitutionen för klinisk neurovetenskap, Sektionen för oftalmologi (creator_code:org_t)

Related titles

  • In:Acta Ophthalmologica Scandinavica83, s. 11-191395-3907

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Sundelin, Karin
Shams, H
Stenevi, Ulf, 19 ...
Articles in the publication
Acta Ophthalmolo ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view