SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lagerstrand Kerstin M)
 

Sökning: WFRF:(Lagerstrand Kerstin M) > (2005-2009) > Quantitative phase-...

Quantitative phase-contrast flow MRI measurements in the presence of a second vessel closely positioned to the examined vessel.

Lagerstrand, Kerstin M (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Vikhoff-Baaz, Barbro (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Starck, Göran (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa fler...
Forssell-Aronsson, Eva, 1961 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
Wiley, 2006
2006
Engelska.
Ingår i: Journal of magnetic resonance imaging : JMRI. - : Wiley. - 1053-1807 .- 1522-2586. ; 23:2, s. 156-62
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To examine the influence of the truncated sampling of k-space data on the accuracy of phase-contrast (PC) flow quantifications in the presence of nearby vessels. MATERIALS AND METHODS: Computer simulations were performed along with some experimental validations on a flow phantom and a normal subject. RESULTS: The accuracy of the PC flow quantification decreased when a second vessel was positioned closely to the examined vessel. The effect strongly depended on the peak flow velocity in the second vessel relative to the velocity encoding (venc) level of the MRI acquisition, and on the position and area of the second vessel. CONCLUSION: Due to the truncated sampling of the k-space data, signal leaked from nearby vessels and distorted the PC flow quantification in the examined vessel. The presented results suggest specific experimental conditions to minimize this flow quantification error.

Nyckelord

Blood Flow Velocity
Blood Vessels
physiology
Computer Simulation
Contrast Media
Humans
Image Interpretation
Computer-Assisted
Magnetic Resonance Imaging
Cine
methods
Phantoms
Imaging
Pulsatile Flow
Reproducibility of Results
Sensitivity and Specificity

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy