SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Gustavsson Sofia)
 

Sökning: WFRF:(Gustavsson Sofia) > STAN in clinical pr...

STAN in clinical practice--the outcome of 2 years of regular use in the city of Gothenburg

Noren, Håkan, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Blad, Sofia (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för fysiologi,Institute of Neuroscience and Physiology, Department of Physiology
Carlsson, Ann (författare)
visa fler...
Flisberg, Anders, 1958 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Gustavsson, Annika (författare)
Lilja, Håkan, 1944 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Wennergren, Margareta, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Hagberg, Henrik, 1955 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2006
2006
Engelska.
Ingår i: Am J Obstet Gynecol. ; 195:1, s. 7-15
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: The purpose of this study was to monitor the introduction of the STAN-methodology (Noventa Medical, Moelndal, Sweden). STUDY DESIGN: This was a prospective observational study covering the total population of deliveries at term during 2 years. Four thousand eight hundred and thirty out of 14,687 term pregnancies were monitored using the STAN S 21 fetal heart monitor and the associated clinical guidelines. Cord artery metabolic acidosis, neonatal outcome, and rates of operative deliveries for fetal distress were assessed. RESULTS: The annual rate of STAN usage increased from 28.1% to 37.7% and was associated with a significant reduction in metabolic acidosis rate in the total population from 0.76% to 0.44% (P < .05). The compliance with the clinical guidelines increased in cases requiring intervention. The rates for moderate/severe hypoxic neonatal encephalopathy were consistently low, 0.55 and 0.68 per 1000 deliveries, respectively, and corresponding to previous findings. The rate of operative delivery did not change during the 2 years in the total population. CONCLUSION: Increasing STAN usage provided consistent improvements in fetal outcome equalling those noted in the Swedish randomized controlled trial (RCT) without increasing operative interventions for fetal distress.

Nyckelord

Acidosis/epidemiology/prevention & control
Apgar Score
Electrocardiography
Female
Fetal Distress/epidemiology/therapy
Fetal Monitoring/*methods/standards
Guideline Adherence
Heart Rate
Fetal
Humans
Incidence
Labor
Induced/statistics & numerical data
Practice Guidelines
Pregnancy
*Pregnancy Outcome
*Signal Processing
Computer-Assisted
Sweden

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy