Search: L773:1475 0961
> (2001-2004) >
Pulmonary gas excha...
Pulmonary gas exchange during exercise in Fontan patients at a long-term follow-up
-
- Strömvall-Larsson, Eva, 1952 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för kvinnors och barns hälsa, Avdelningen för pediatrik,Institute for the Health of Women and Children, Dept of Paediatrics
-
Eriksson, B. O. (author)
-
- Holmgren, Daniel, 1945 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för kvinnors och barns hälsa, Avdelningen för pediatrik,Institute for the Health of Women and Children, Dept of Paediatrics
-
show more...
-
- Sixt, Rune (author)
- Gothenburg University,Göteborgs universitet,Institutionen för kvinnors och barns hälsa, Avdelningen för pediatrik,Institute for the Health of Women and Children, Dept of Paediatrics
-
show less...
-
(creator_code:org_t)
- 2004
- 2004
- English.
-
In: Clin Physiol Funct Imaging. - 1475-0961. ; 24:6, s. 327-34
- Related links:
-
https://gup.ub.gu.se...
Abstract
Subject headings
Close
- Desaturation during exercise in the Fontan type of circulation may be due to known right-to-left shunts in some patients, while in others there are no obvious signs of shunts. AIM: To evaluate the gas exchange and exercise capacity in patients with Fontan circulation. MATERIAL AND METHODS: Twenty patients with the Fontan type of circulation, median age at operation 7.5 years (3.0-35 years), follow-up time 12.1 years (8.3-20.4 years), were included. The intrapulmonary gas mixing (N(2)-slope) and diffusion capacity for carbon monoxide (D(LCO)) was evaluated and determination of cardiac output was performed at rest and during exercise with measurements of ventilation, oxygen uptake, respiratory rate, carbon dioxide production and heart rate. Samples for blood gases (P(a)O(2), S(a)O(2)) were obtained at rest and at the end of each work load. RESULTS: The median exercise capacity was 1.47 l min(-1). During exercise, all the patients had an alveolar-arterial oxygen partial pressure difference (P(A-a)O(2)) above 2 SD. Patients with known right-to-left shunts had lower P(a)O(2) and S(a)O(2) values and higher P(A-a)O(2) values both at rest, median 7.5 kPa, 90%, and 7.2 kPa, respectively, and during exercise, median 5.8 kPa, 77% and 10.1 kPa, compared with those with no shunts, median 11.2 kPa, 97% and 4.1, respectively, at rest and 9.7 kPa, 94%, and 6.3 during exercise (P<0.01). No correlation was found between cardiac index, the N(2)-slope or the D(LCO) at rest and the P(a)O(2) and S(a)O(2) at rest or during exercise. CONCLUSION: In patients with the Fontan type of circulation, right-to-left shunts are the major cause of desaturation during exercise.
Keyword
- Adolescent
- Adult
- Child
- Child
- Preschool
- Exercise Test
- *Exertion
- Female
- Follow-Up Studies
- *Fontan Procedure
- Heart Defects
- Congenital/*physiopathology/*surgery
- Humans
- Longitudinal Studies
- Male
- Middle Aged
- *Oxygen Consumption
- *Physical Endurance
- *Pulmonary Gas Exchange
- Treatment Outcome
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database