  • Rylander, Christian,1960Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care (author)

Uneven distribution of ventilation in acute respiratory distress syndrome

  • Article/chapterEnglish2005

Publisher, publication year, extent ...

  • 2005

Numbers

  • LIBRIS-ID:oai:gup.ub.gu.se/60192
  • https://gup.ub.gu.se/publication/60192URI

Supplementary language notes

  • Language:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • INTRODUCTION: The aim of this study was to assess the volume of gas being poorly ventilated or non-ventilated within the lungs of patients treated with mechanical ventilation and suffering from acute respiratory distress syndrome (ARDS). METHODS: A prospective, descriptive study was performed of 25 sedated and paralysed ARDS patients, mechanically ventilated with a positive end-expiratory pressure (PEEP) of 5 cmH2O in a multidisciplinary intensive care unit of a tertiary university hospital. The volume of poorly ventilated or non-ventilated gas was assumed to correspond to a difference between the ventilated gas volume, determined as the end-expiratory lung volume by rebreathing of sulphur hexafluoride (EELVSF6), and the total gas volume, calculated from computed tomography images in the end-expiratory position (EELVCT). The methods used were validated by similar measurements in 20 healthy subjects in whom no poorly ventilated or non-ventilated gas is expected to be found. RESULTS: EELVSF6 was 66% of EELVCT, corresponding to a mean difference of 0.71 litre. EELVSF6 and EELVCT were significantly correlated (r2 = 0.72; P < 0.001). In the healthy subjects, the two methods yielded almost identical results. CONCLUSION: About one-third of the total pulmonary gas volume seems poorly ventilated or non-ventilated in sedated and paralysed ARDS patients when mechanically ventilated with a PEEP of 5 cmH2O. Uneven distribution of ventilation due to airway closure and/or obstruction is likely to be involved.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Tylén, Ulf,1938Gothenburg University,Göteborgs universitet,Institutionen för särskilda specialiteter, Avdelningen för radiologi,Institute of Selected Clinical Sciences, Department of Radiology(Swepub:gu)xtyleu (author)
  • Rossi-Norrlund, Rauni,1962Gothenburg University,Göteborgs universitet,Institutionen för särskilda specialiteter, Avdelningen för radiologi,Institute of Selected Clinical Sciences, Department of Radiology(Swepub:gu)xrosra (author)
  • Herrmann, P. (author)
  • Quintel, M. (author)
  • Bake, Björn,1939Gothenburg University,Göteborgs universitet,Institutionen för invärtesmedicin, Avdelningen för lungmedicin och allergologi,Institute of Internal Medicine, Dept of Respiratory Medicine/Allergology(Swepub:gu)xbakbj (author)
  • Göteborgs universitetInstitutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård (creator_code:org_t)

Related titles

  • In:Crit Care9:2

Internet link

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Rylander, Christ ...
Tylén, Ulf, 1938
Rossi-Norrlund, ...
Herrmann, P.
Quintel, M.
Bake, Björn, 193 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
Articles in the publication
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view