SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0174 1551
 

Sökning: L773:0174 1551 > (2005-2009) > Porcine transfer st...

Porcine transfer study: virtual reality simulator training compared with porcine training in endovascular novices

Berry, Max, 1969 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Lystig, T (författare)
Beard, J (författare)
visa fler...
Klingestierna, H (författare)
Reznick, R (författare)
Lönn, Lars, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2007-01-12
2007
Engelska.
Ingår i: Cardiovasc Intervent Radiol. - : Springer Science and Business Media LLC. - 0174-1551. ; 30:3, s. 455-61
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To compare the learning of endovascular interventional skills by training on pig models versus virtual reality simulators. METHODS: Twelve endovascular novices participated in a study consisting of a pig laboratory (P-Lab) and a virtual reality laboratory (VR-Lab). Subjects were stratified by experience and randomized into four training groups. Following 1 hr of didactic instruction, all attempted an iliac artery stenosis (IAS) revascularization in both laboratories. Onsite proctors evaluated performances using task-specific checklists and global rating scales, yielding a Total Score. Participants completed two training sessions of 3 hr each, using their group's assigned method (P-Lab x 2, P-Lab + VR-Lab, VR-Lab + P-Lab, or VR-Lab x 2) and were re-evaluated in both laboratories. A panel of two highly experienced interventional radiologists performed assessments from video recordings. ANCOVA analysis of Total Score against years of surgical, interventional radiology (IR) experience and cumulative number of P-Lab or VR-Lab sessions was conducted. Inter-rater reliability (IRR) was determined by comparing proctored scores with the video assessors in only the VR-Lab. RESULTS: VR-Lab sessions improved the VR-Lab Total Score (beta = 3.029, p = 0.0015) and P-Lab Total Score (beta = 1.814, p = 0.0452). P-Lab sessions increased the P-Lab Total Score (beta = 4.074, p < 0.0001) but had no effect on the VR-Lab Total Score. In the general statistical model, both P-Lab sessions (beta = 2.552, p = 0.0010) and VR-Lab sessions (beta = 2.435, p = 0.0032) significantly improved Total Score. Neither previous surgical experience nor IR experience predicted Total Score. VR-Lab scores were consistently higher than the P-Lab scores (Delta = 6.659, p < 0.0001). VR-Lab IRR was substantial (r = 0.649, p < 0.0008). CONCLUSIONS: Endovascular skills learned in the virtual environment may be transferable to the real catheterization laboratory as modeled in the P-Lab.

Nyckelord

Adult
Angioplasty
Balloon/*education
Animals
Arterial Occlusive Diseases/*therapy
Attitude of Health Personnel
*Computer Simulation
Curriculum
*Disease Models
Animal
Female
Humans
*Iliac Artery
Male
Middle Aged
Radiology
Interventional/*education
*Stents
Swine
*User-Computer Interface

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy