- This field study aimed to evaluate the prevalence of annoyance and disturbance and the subjective perception of the sound environment due to noise, in an old and a new control room at a large paper mill. Working in a control room requires sustained attention and concentration and, in the case of error messages, rapid and correct decisions. In this study, the personnel's responses were collected by questionnaire, and detailed sound measurements were taken in both control rooms. The A-weighted sound pressure level in the new control room was 54.9 dB, a reduction from the 63.5 dB measured in the old room, and the C-weighted sound pressure level was 66.8 dB, a reduction from the 75.2 dB measured in the old room. The new control room was rated as being a less noisy environment; however, the personnel did complain about noise from other computers/equipment, radios, and the new laboratory.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)