SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sennerby L)
 

Sökning: WFRF:(Sennerby L) > Osseointegration of...

Osseointegration of oxidized and turned implants in circumferential bone defects with and without adjunctive therapies: an experimental study on BMP-2 and autogenous bone graft in the dog mandible

Salata, L.A. (författare)
Miranda Burgos, Patricia, 1970 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Rasmusson, Lars, 1962 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa fler...
Novaes, A.B. (författare)
Papalexiou, V. (författare)
Dahlin, Christer, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Sennerby, Lars, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - : Elsevier BV. - 0901-5027. ; 36:1, s. 62-71
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of the study was to compare the integration and implant stability of turned and oxidized titanium implants when placed in experimental bone defects with autogenous bone graft, BMP-2 or without adjunctive therapy. Four defects were prepared on each side of the mandible of 12 mongrel dogs five months after tooth extractions. Implants with turned and oxidized surfaces were placed in the defects. The circumferential gaps were filled with either autogenous bone grafts, a BMP-allogeneic dog mixture in a thermoplastic carrier, carrier alone or left without any treatment (control). There were no statistically significant differences between control and treated sites, neither for turned nor for oxidized implants with regard to histomorphometric measurements in ground sections and to implant stability as measured with resonance frequency analysis (RFA) after 4 and 12 weeks of healing. However, oxidized implants showed a significantly higher stability after 4 weeks and a tendency (p < 0.1) of that after 12 weeks. Histomorphometry showed more bone contacts for oxidized than for turned implants. It is concluded that oxidized implants gain stability more rapidly and integrate with more bone contacts than implants with a turned surface when placed in bone defects.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

human osteogenic protein-1
titanium implants
extraction sockets
surface characteristics
miniature pigs
augmentation
integration
adjacent

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy