Comparison of the PainMatcher and the Visual Analogue Scale for assessment of labour pain following administered pain relief treatment.
-
- Bergh, Ingrid, 1956 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för vårdvetenskap och hälsa,Institute of Health and Care Sciences,Institute of Health and Care Sciences, Sahlgrenska Academy, University of Gothenburg
-
- Stener-Victorin, Elisabet, 1964 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för fysiologi,Institute of Neuroscience and Physiology, Department of Physiology,Institute of Neuroscience and Physiology/Endocrinology, Sahlgrenska Academy, University of Gothenburg
-
- Wallin, Gunnar, 1952 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology,Institute of Clinical Sciences, Department of Obstetrics and Gynaecology, Sahlgrenska Academy, University of Gothenburg
-
visa fler...
-
- Mårtensson, Lena, 1958 (författare)
- Högskolan i Skövde,Gothenburg University,Göteborgs universitet,Institutionen för vårdvetenskap och hälsa,Institute of Health and Care Sciences,Institutionen för vård och natur
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2011
- 2011
- Engelska.
-
Ingår i: Midwifery. - : Elsevier BV. - 1532-3099 .- 0266-6138. ; 27:1
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVE: during childbirth, it is necessary to assess and monitor experienced pain and to evaluate the effect of pain relief treatment. The aim of this study was to compare the PainMatcher((R)) (PM) with the Visual Analogue Scale (VAS) for the assessment of labour pain and the effect of pain relief treatment. DESIGN: randomised controlled trial. SETTING: labour ward with approximately 2500 childbirths per year in western Sweden. PARTICIPANTS: 57 women with labour pain treated with acupuncture or sterile water injections scored their electrical pain threshold and pain intensity with the PM. Pain intensity was also assessed with the VAS. Electrical pain threshold and pain intensity were assessed immediately after a uterine contraction before and 30, 60, 90, 120, 150 and 180minutes after treatment. MEASUREMENTS AND FINDINGS: the results showed a weak correlation (r=0.13, p<0.05) between the pain intensity scores on the PM and the VAS. The PM detected changes (decrease) in pain intensity to a lower degree than the VAS. Surprisingly, in over 10% of sessions, women scored their pain intensity during a uterine contraction lower than their electrical pain threshold with the PM. However, electrical pain thresholds with the PM correlated well throughout all measurements. CONCLUSIONS: the PM is a reliable tool for the assessment of electrical pain threshold; however, the VAS is more sensitive than the PM for recording changes in pain intensity when assessing the effects of treatment on labour pain. IMPLICATIONS FOR PRACTICE: the PM and the VAS are not interchangeable in the case of labour pain, and there is still a need for research in this area to find a more suitable assessment instrument for the evaluation of labour pain.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Omvårdnad (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Nursing (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)
Nyckelord
- Pain assessment
- Visual AnalogueScale
- PainMatcher
- Labour pain
- Pain assessment
- Medical sciences