Natural refrigerant mixtures in low-charge heat pumps: An analysis of the potential for performance enhancements

Caramaschi, Matteo (författare)
METRO THERM A/S, Helsinge, Denmark; Technical University of Denmark, Lyngby, Denmark
Jensen, Jonas Kjær (författare)
Technical University of Denmark, Lyngby, Denmark
Poppi, Stefano (författare)
NIBE A/B, Markaryd, Sweden
visa fler...
Østergaard, Kasper Korsholm (författare)
METRO THERM A/S, Helsinge, Denmark
Ommen, Torben Schmidt (författare)
Sensible Energy, Ballerup, Denmark
Kærn, Martin Ryhl (författare)
IPU, Lyngby, Denmark
Madani Larijani, Hatef (författare)
KTH,Tillämpad termodynamik och kylteknik
Elmegaard, Brian (författare)
Technical University of Denmark, Lyngby, Denmark
visa färre...
 (creator_code:org_t)
Elsevier BV, 2024
2024
Engelska.
Ingår i: International journal of refrigeration. - : Elsevier BV. - 0140-7007 .- 1879-2081. ; 165, s. 70-83
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The study investigated the characteristics of different natural refrigerants and their mixtures in a residential heat pump with low refrigerant charge. Three main evaluation criteria were utilized for comparing different mixtures: Coefficient of Performance (COP), Volumetric Heating Capacity (VHC), and a newly proposed indicator, the heating capacity at charge limit. Propane was used as a reference refrigerant. It was found that some mixtures significantly improved both COP and the heating capacity at charge limit while maintaining similar volumetric heating capacity and operating conditions. Alternative multi-criteria decision-making techniques were adopted to rank the best refrigerant mixtures. Mixtures rich in Dimethyl Ether (DME), such as DME-CO2 [0.96-0.04] and DME-Propylene [0.75-0.25] were found consistently among the best options. Those were followed by Propylene-rich mixtures such as Propylene-CO2, Propylene-Isobutane and Propylene-Butane. The levelized cost of heat (LCOH) could be improved by up to 12 %. To accelerate the transition to natural refrigerants, without compromises on efficiency and costs, further research and certification activities on non-fluorinated refrigerants based on Dimethyl Ether (R-E170), CO2 (R-744) and Propylene (R-1270) are recommended.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Capacity
Flammability
Heat pumps
Low-charge
Mixtures
Natural refrigerants

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy