Search: L773:1873 376X OR L773:1570 0232 > (2005-2009) > Determination of sh...

Determination of short-chain fatty acids in serum by hollow fiber supported liquid membrane extraction coupled with gas chromatography

Zhao, Guohua (author)
Lund University,Lunds universitet,Avdelningen för livsmedel och läkemedel,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Food and Pharma,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Liu, Jing-Fu (author)
Nyman, Margareta (author)
Lund University,Lunds universitet,Avdelningen för livsmedel och läkemedel,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Food and Pharma,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
show more...
Jönsson, Jan Åke (author)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
Elsevier BV, 2007
2007
English.
In: Journal of Chromatography. B. - : Elsevier BV. - 1873-376X .- 1570-0232. ; 846:1-2, s. 202-208
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A method based on hollow fiber supported liquid membrane extraction coupled with a gas chromatograph equipped with flame ionization detector (GC-FID) was developed for the determination of six short-chain fatty acids including acetic acid, propionic acid, i-butyric acid, n-butyric acid, i-valeric acid and n-valeric acid in serum. Hollow fiber supported liquid membrane extraction was employed for preconcentration and clean-up of the samples. The fatty acids were extracted from the acidic donor (diluted serum) into a liquid membrane formed in the wall of the hollow fiber with 10% tri-n-octylphoshphine oxide (TOPO) in di-n-hexyl ether, and then extracted back into a basic acceptor solution filled in the lumen of the hollow fiber. After being acidified with HCl, the acceptor was directly analyzed by GC-FID. The acceptor concentration, donor pH, membrane liquid and extracting time were optimized giving an enrichment factor up to 155 times. The good linearity (r2 > 0.980), reasonable recovery (87.2-121%), and satisfactory intra-assay (8.2-11.5%) and inter-assay (6.1-11.6%) precision illustrated the good performance of the present method. Limits of detection (LOD) ranged from 0.04 to 0.24 μM and limits of quantification (LOQ) varied from 0.13 to 0.80 μM.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Näringslära (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Nutrition and Dietetics (hsv//eng)
NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Keyword

Quantitative analysis
Gas chromatography
Short chain
Determination
Fatty acids
Lipids
Biological fluid

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Zhao, Guohua
Liu, Jing-Fu
Nyman, Margareta
Jönsson, Jan Åke
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Health Sciences
and Nutrition and Di ...
NATURAL SCIENCES
NATURAL SCIENCES
and Chemical Science ...
and Analytical Chemi ...
Articles in the publication
Journal of Chrom ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view