Search: L773:1873 376X OR L773:1570 0232
> (2005-2009) >
Determination of sh...
Determination of short-chain fatty acids in serum by hollow fiber supported liquid membrane extraction coupled with gas chromatography
-
- Zhao, Guohua (author)
- Lund University,Lunds universitet,Avdelningen för livsmedel och läkemedel,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Food and Pharma,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Liu, Jing-Fu (author)
-
- Nyman, Margareta (author)
- Lund University,Lunds universitet,Avdelningen för livsmedel och läkemedel,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Food and Pharma,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
show more...
-
- Jönsson, Jan Åke (author)
- Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
show less...
-
(creator_code:org_t)
- Elsevier BV, 2007
- 2007
- English.
-
In: Journal of Chromatography. B. - : Elsevier BV. - 1873-376X .- 1570-0232. ; 846:1-2, s. 202-208
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- A method based on hollow fiber supported liquid membrane extraction coupled with a gas chromatograph equipped with flame ionization detector (GC-FID) was developed for the determination of six short-chain fatty acids including acetic acid, propionic acid, i-butyric acid, n-butyric acid, i-valeric acid and n-valeric acid in serum. Hollow fiber supported liquid membrane extraction was employed for preconcentration and clean-up of the samples. The fatty acids were extracted from the acidic donor (diluted serum) into a liquid membrane formed in the wall of the hollow fiber with 10% tri-n-octylphoshphine oxide (TOPO) in di-n-hexyl ether, and then extracted back into a basic acceptor solution filled in the lumen of the hollow fiber. After being acidified with HCl, the acceptor was directly analyzed by GC-FID. The acceptor concentration, donor pH, membrane liquid and extracting time were optimized giving an enrichment factor up to 155 times. The good linearity (r2 > 0.980), reasonable recovery (87.2-121%), and satisfactory intra-assay (8.2-11.5%) and inter-assay (6.1-11.6%) precision illustrated the good performance of the present method. Limits of detection (LOD) ranged from 0.04 to 0.24 μM and limits of quantification (LOQ) varied from 0.13 to 0.80 μM.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Näringslära (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Nutrition and Dietetics (hsv//eng)
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
Keyword
- Quantitative analysis
- Gas chromatography
- Short chain
- Determination
- Fatty acids
- Lipids
- Biological fluid
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database