SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ronchi Enrico)
 

Sökning: WFRF:(Ronchi Enrico) > The use of multi-zo...

The use of multi-zone modelling for tunnel fires

Johansson, Nils (författare)
Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Ronchi, Enrico (författare)
Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Trafik och väg,Institutionen för teknik och samhälle,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH,Transport and Roads,Department of Technology and Society,Faculty of Engineering, LTH
Scozzari, Rugiada (författare)
Cantene Srl
visa fler...
Fronterrè, Michele (författare)
Cantene Srl
visa färre...
 (creator_code:org_t)
Elsevier BV, 2023
2023
Engelska.
Ingår i: Tunnelling and Underground Space Technology. - : Elsevier BV. - 0886-7798. ; 134
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper introduces the use of a multi-zone modelling approach for analysing smoke spread in tunnels. The approach suggested in this paper is based on an existing model, i.e., the Multi-Zone Fire model developed for large spaces. The Multi-Zone Fire model has been adapted and modified for tunnel fire scenarios by including features that consider longitudinal ventilation flow, tunnel gradient and tunnel section representations. An evaluation of the model has been conducted through benchmarking against experimental data from the BeNeLux tunnel experiments and the Runehamar tunnel fire experiments. The results from the Multi-Zone Fire model results were also compared against results from the Fire Dynamics Simulator. The results of the benchmarking exercise indicate that the multi-zone approach can be a time-efficient and useful tool for studying tunnel fire dynamics. The Multi-Zone Fire model performs well 50–200 m from the fire for heat release rates of 5–20 MW and moderate longitudinal ventilation flows. The model results are more conservative for the studied scenario with a higher heat release rate.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Nyckelord

Fire
Fire dynamics simulator
Multi-zone modelling
Risk analysis
Tunnel safety

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Johansson, Nils
Ronchi, Enrico
Scozzari, Rugiad ...
Fronterrè, Miche ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
Artiklar i publikationen
Tunnelling and U ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy