Sökning: L773:1759 9660 OR L773:1759 9679 >
A new analytical me...
A new analytical method for lead determination in atmospheric particulate matter by a combination of ultrasound-assisted extraction and supramolecular solvent preconcentration
-
- Beal, Alexandra (författare)
- State University of Londrina
-
- Garcia De Almeida, Fernanda (författare)
- State University of Londrina
-
- Moreira, Camila A.B. (författare)
- Federal Technological University Of Paraná
-
visa fler...
-
- Santos, Isis M. (författare)
- Federal Technological University Of Paraná
-
- Curti, Suzana M.M. (författare)
- Federal Technological University Of Paraná
-
- Martins, Leila D. (författare)
- Lund University,Lunds universitet,Centrum för miljö- och klimatvetenskap (CEC),Naturvetenskapliga fakulteten,Centre for Environmental and Climate Science (CEC),Faculty of Science,Federal Technological University Of Paraná
-
- Tarley, Cesar R.T. (författare)
- University of Campinas,State University of Londrina
-
visa färre...
-
(creator_code:org_t)
- 2018
- 2018
- Engelska 9 s.
-
Ingår i: Analytical Methods. - : Royal Society of Chemistry (RSC). - 1759-9660 .- 1759-9679. ; 10:30, s. 3745-3753
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Air pollution by lead, even in small concentrations, can cause serious health effects. In the atmosphere this element can generally be found in particulate matter (PM), and in general in small concentrations. This work proposes the development of an analytical method for lead determination in inhaled PM based on ultrasound-assisted extraction with subsequent supramolecular solvent based dispersive liquid-liquid microextraction (SM-DLLME), using reverse micelles of dodecanoic acid as an extractor dispersed in a continuous phase of tetrahydrofuran (THF)/water. The rich phase was then analyzed by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) coupled on-line to a flow injection analysis (FIA). An analytical curve in the range of 15.0-200.0 μg L-1 (R2 = 0.999), an enrichment factor of 18.1 times and the limits of detection (LOD) and quantification (LOQ) equal to 3.7 and 11.3 μg L-1, respectively, were obtained. The accuracy of the method was successfully attested by comparing with EDX analysis through the paired t-test at a confidence level of 95%. The amount of lead determined in the samples of PM collected in different environments varied from 19.3 to 94.8 ng m-3.
Ämnesord
- NATURVETENSKAP -- Geovetenskap och miljövetenskap (hsv//swe)
- NATURAL SCIENCES -- Earth and Related Environmental Sciences (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas