Tibial Component Undersizing Is Related to High Degrees of Implant Migration Following Cementless Total Knee Arthroplasty : A Study of Radiostereometric Analysis Data for 111 Patients with 2-Year Follow-up

Andersen, Mikkel Rathsach (författare)
Gentofte Hospital
Winther, Nikolaj (författare)
Copenhagen University Hospital
Lind, Thomas (författare)
Gentofte Hospital
visa fler...
Schrøder, Henrik (författare)
University of Southern Denmark
Flivik, Gunnar (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Forskningsgruppen för höft- och knäproteskirurgi,Forskargrupper vid Lunds universitet,LU profilområde: Ljus och material,Lunds universitets profilområden,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,The Hip and Knee Joint Arthroplasty Research Group,Lund University Research Groups,LU Profile Area: Light and Materials,Lund University Profile areas,Skåne University Hospital
Petersen, Michael Mørk (författare)
Copenhagen University Hospital
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: JBJS Open Access. - 2472-7245. ; 8:3
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Radiostereometric analysis (RSA) studies have shown that the continuous migration of tibial components is predictive of aseptic loosening following total knee arthroplasty (TKA). In the present study, we investigated whether accurate sizing and placement of tibial components are related to the degree of implant migration as measured with use of RSA.Methods:A total of 111 patients who underwent TKA surgery with a cementless tibial component were followed for a period of 2 years postoperatively, during which implant migration was assessed with use of RSA. RSA was performed within 7 days postoperatively and after 3, 6, 12, and 24 months. Postoperative radiographs were evaluated for component size and placement in the tibia. The evaluations were performed by experienced knee surgeons who were blinded to the migration data and clinical outcomes. A multivariable linear regression analysis was conducted.Results:Continuous implant migration (i.e., migration occurring between 12 and 24 months postoperatively) had a negative association with tibial component size (coefficient [B], -0.2; 95% confidence interval [CI], -0.33 to -0.08). Subsidence was associated with the absence of posterior cortical bone support (B, -0.7; 95% CI, -1.09 to -0.28), the absence of lateral cortical bone support (B, 0.8; 95% CI, 0.29 to 1.37), frontal-plane varus malalignment (B, 0.6; 95% CI, 0.12 to 1.16), and component undersizing (B, -0.4; 95% CI, -0.06 to -0.68). Posterior tilt was associated only with undersizing (B, 0.6; 95% CI, 0.27 to 1.11).Conclusions:Undersized cementless tibial components are at a higher risk for poor fixation with continuous migration following TKA. Therefore, a higher risk of aseptic loosening should be expected.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy