SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Jokubkiene Ligita)
 

Sökning: WFRF:(Jokubkiene Ligita) > (2020-2023) > Fusion imaging in b...

Fusion imaging in brain structure measurements on a fetus phantom, combining real-time ultrasound with magnetic resonance imaging

Arechvo, Anastasija (författare)
Lund University,Lunds universitet,Obstetrik och gynekologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Obstetrics and Gynaecology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Lingman, Göran (författare)
Lund University,Lunds universitet,Obstetrik och gynekologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Obstetrics and Gynaecology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Thurn, Lars (författare)
Lund University,Lunds universitet,Obstetrik och gynekologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Obstetrics and Gynaecology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
visa fler...
Jansson, Tomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Medicinsk teknik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Biomedical Engineering, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Jokubkiene, Ligita (författare)
Lund University,Lunds universitet,Urogynekologi och reproduktionsfarmakologi,Forskargrupper vid Lunds universitet,Urogynaecology and Reproductive Pharmacology,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
2021-05-25
2021
Engelska.
Ingår i: Australasian Journal of Ultrasound in Medicine. - : Wiley. - 1836-6864 .- 2205-0140. ; 24:3, s. 161-172
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: To assess synchronisation of MRI and US in measuring foetus phantom head structures; inter-method, intra- and inter-observer differences on biparietal diameter (BPD), head diameter, anterio-posterior head diameter (HAP) and lateral ventricle structures (VS). Methods: Fusion Imaging (FI) has been performed by combining MRI and US simultaneously. Axial scans of 1.5 Tesla MRI on a foetus phantom were acquired and uploaded on a US machine (EPIQ 7G, Philips). A PercuNav US tracker allowed the system to recognise and display the position of the transducer. A fetal phantom tracker was used as a phantom reference. Real-time US of the phantom head was performed by synchronising the uploaded MRI images using different landmarks. Synchronisation has been assessed by taking measurements after rotating the US probe by 90. Measurements were taken by three different observers twice. Differences in measurements between MRI and US, inter-, intra-observer differences in all measurements were assessed. Results: BPD, HAP and VS measurements before rotation were 0.13 ± 0.06 cm, 0.46 ± 0.09 cm and 0.4 ± 0.23 cm (width) and mean 0.6 ± 0.25 cm (length) larger at MRI than at US using any number of landmarks. After US probe rotation VS were 0.3 ± 0.24 cm in width and 0.3 ± 0.27 cm in length. Intra- and inter-observer differences in all measurements were small. Conclusions: FI showed good synchronisation in measurements. BPD, HAP and VS were larger at MRI than US, likely a result of the way images are generated. Intra-, inter-observer differences between measurements were small. This can be important when reporting geometric measures from FI.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

fetal brain
fusion imaging
MRI
phantom
ultrasound

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy