SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Seemann Felicia)
 

Sökning: WFRF:(Seemann Felicia) > Non-invasive quanti...

Non-invasive quantification of pressure-volume loops from cardiovascular magnetic resonance at rest and during dobutamine stress

Sjöberg, Pia (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Seemann, Felicia (författare)
Lund University,Lunds universitet,Hjärt-MR-gruppen i Lund,Forskargrupper vid Lunds universitet,Lund Cardiac MR Group,Lund University Research Groups,Skåne University Hospital
Arheden, Håkan (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
visa fler...
Heiberg, Einar (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,WCMM- Wallenberg center för molekylär medicinsk forskning,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,WCMM-Wallenberg Centre for Molecular Medicine,Skåne University Hospital
visa färre...
 (creator_code:org_t)
2021-06-30
2021
Engelska 4 s.
Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 41:5, s. 467-470
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Non-invasive quantification of pressure-volume (PV) loops from brachial pressure and cardiovascular magnetic resonance is a validated method but its application has been limited to resting heart rates. The aim of this study was to improve the previous method and validate it against invasive left-ventricular pressure measurements in an experimental porcine model, and further apply it to 16 healthy humans at rest and during dobutamine stress. In addition, the improved method calculates the arterial elastance which provides the computation of the ratio of effective arterial (Ea) to maximal ventricular elastance (Emax) representing the ventricular-arterial coupling. In the porcine model, the differences between the improved non-invasively derived PV loops and invasively measured PV loops were for stroke work (mean ± SD) 0.00 ± 0.03 J, ventricular efficiency −1.1 ± 0.4%, and contractility 1.1 ± 0.1 mmHg/ml. In human subjects during dobutamine stress, stroke work increased from 1.3 ± 0.3 to 1.7 ± 0.4 J, ventricular efficiency from 71 ± 4 to 82 ± 4%, contractility from 1.3 ± 0.2 to 2.3 ± 0.6 mmHg/ml, and the ratio of arterial to ventricular elastance decreased from 0.96 to 0.56. The improved method for non-invasive PV loops constitutes a more robust diagnostic tool for cardiac disease states in a wider range of study cohorts at both rest and during stress.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

contractility
stress
stroke work
validation
ventricular efficiency

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sjöberg, Pia
Seemann, Felicia
Arheden, Håkan
Heiberg, Einar
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy