SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Drake D)
 

Sökning: WFRF:(Drake D) > (1995-1999) > Reliability of isok...

Reliability of isokinetic ankle dorsiflexor strength measurements in healthy young men and women

Drake, Anna Maria (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
Porter, M M (författare)
Department of Physical Therapy, Lund University
Downham, D (författare)
Department of Physical Therapy, Lund University
visa fler...
Lexell, Jan (författare)
Lund University,Lunds universitet,Neurokirurgi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurosurgery,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Holmbäck, Anna-Maria (författare)
Department of Physical Therapy, Lund University
visa färre...
 (creator_code:org_t)
Informa UK Limited, 1999
1999
Engelska.
Ingår i: Scandinavian Journal of Rehabilitation Medicine. - : Informa UK Limited. - 0036-5505 .- 1940-2228. ; 31:4, s. 229-239
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purposes of this study were: (i) to determine the test-retest reliability of isokinetic ankle dorsiflexor strength measurements in young healthy adults using the Biodex dynamometer, and (ii) to examine several statistical measures for the interpretation of reliability. Thirty men and women (mean age 23 +/- 3 years) performed three maximal concentric contractions at 30 degrees/s, 60 degrees/s, 90 degrees/s, 120 degrees/s and 150 degrees/s. Reliability of peak torque, work and torque at a specific time were assessed by calculating the intraclass correlation coefficient (ICC 2,1), Pearson product moment correlation coefficient (r), standard error of the measurement (SEM), method error (ME) and coefficient of variation (CV), and by plotting the differences between observations against their means. Isokinetic tests of ankle dorsiflexor strength in healthy young adults using the Biodex dynamometer were highly reliable (ICC 0.61-0.93). It is recommended that test-retest reliability analyses include the ICC and assessments of measurement errors (SEM, ME or CV), as well as graphs to indicate any systematic variations in the data.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Drake, Anna Mari ...
Porter, M M
Downham, D
Lexell, Jan
Holmbäck, Anna-M ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Sjukgymnastik
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Neurologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Scandinavian Jou ...
Av lärosätet
Lunds universitet
Luleå tekniska universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy