SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Yu Liping)
 

Sökning: WFRF:(Yu Liping) > (2015-2019) > Determination of 21...

Determination of 21-hydroxylase autoantibodies: inter-laboratory concordance in the Euradrenal International Serum Exchange Program

Falorni, Alberto (författare)
Univ Perugia, Dept Med, I-06126 Perugia, Italy.
Bini, Vittorio (författare)
Univ Perugia, Dept Med, I-06126 Perugia, Italy.
Betterle, Corrado (författare)
Univ Padua, Dept Med, Endocrine Unit, Padua, Italy.
visa fler...
Brozzetti, Annalisa (författare)
Univ Perugia, Dept Med, I-06126 Perugia, Italy.
Castano, Luis (författare)
Univ Basque Country, Cruces Univ Hosp, Ciberdem, BioCruces, Bilbao, Spain.
Fichna, Marta (författare)
Poznan Univ Med Sci, Dept Endocrinol & Metab, Poznan, Poland.;Polish Acad Sci, Inst Human Genet, PL-60479 Poznan, Poland.
Kämpe, Olle (författare)
Karolinska Institutet,Uppsala universitet,Autoimmunitet,Science for Life Laboratory, SciLifeLab
Mellgren, Gunnar (författare)
Haukeland Hosp, Hormone Lab, N-5021 Bergen, Norway.;Univ Bergen, Dept Clin Sci, Bergen, Norway.
Peterson, Part (författare)
Univ Tartu, Inst Biomed & Translat Med, Mol Pathol, EE-50090 Tartu, Estonia.
Chen, Shu (författare)
RSR Ltd, FIRS Labs, Cardiff, S Glam, Wales.
Rönnelid, Johan (författare)
Uppsala universitet,Klinisk immunologi
Seissler, Jochen (författare)
Klinikum Univ Munchen, Med Klin & Poliklin 4, Diabet Zentrum, Munich, Germany.
Tiberti, Claudio (författare)
Univ Roma La Sapienza, Dept Expt Med, I-00185 Rome, Italy.
Uibo, Raivo (författare)
Univ Tartu, Inst Biomed & Translat Med, Dept Immunol, EE-50090 Tartu, Estonia.
Yu, Liping (författare)
Univ Colorado Denver, Barbara Davis Ctr Diabet, Aurora, CO USA.
Lernmark, Åke (författare)
Lund University,Lunds universitet,Celiaki och diabetes,Forskargrupper vid Lunds universitet,Celiac Disease and Diabetes Unit,Lund University Research Groups,Lund Univ, Skane Univ Hosp, Dept Clin Sci, Malmo, Sweden.
Husebye, Eystein (författare)
Univ Bergen, Dept Clin Sci, Bergen, Norway.;Haukeland Hosp, Dept Med, N-5021 Bergen, Norway.
visa färre...
Univ Perugia, Dept Med, I-06126 Perugia, Italy Univ Padua, Dept Med, Endocrine Unit, Padua, Italy. (creator_code:org_t)
Walter de Gruyter GmbH, 2015
2015
Engelska.
Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 53:11, s. 1761-1770
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: 21-Hydroxylase autoantibodies (21OHAb) are markers of an adrenal autoimmune process that identifies individuals with autoimmune Addison's disease (AAD). Quality and inter-laboratory agreement of various 21OHAb tests are incompletely known. The objective of the study was to determine inter-laboratory concordance for 21OHAb determinations. Methods: Sixty-nine sera from 51 patients with AAD and 51 sera from 51 healthy subjects were blindly coded by a randomization center and distributed to 14 laboratories that determined 21OHAb, either by an "in-house" assay (n=9) using in vitro-translated S-35-21OH or luciferase-labeled 21OH or a commercial kit with I-125-21OH (n=5). Main outcome measures were diagnostic accuracy of each participating laboratory and inter-laboratory agreement of 21OHAb assays. Results: Intra-assay coefficient of variation ranged from 2.6% to 5.3% for laboratories using the commercial kit and from 5.1% to 23% for laboratories using "in-house" assays. Diagnostic accuracy, expressed as area under ROC curve (AUC), varied from 0.625 to 0.947 with the commercial kit and from 0.562 to 0.978 with "in-house" methods. Cohen's. of inter-rater agreement was 0.603 among all 14 laboratories, 0.691 among "in-house" laboratories, and 0.502 among commercial kit users. Optimized cutoff levels, calculated on the basis of AUCs, increased the diagnostic accuracy of every laboratory (AUC >0.9 for 11/14 laboratories) and increased the Cohen's. of inter-rater agreement. Discrepancies in quantitation of 21OHAb levels among different laboratories increased with increasing autoantibody levels. Conclusions: The quality of 21OHAb analytical procedures is mainly influenced by selection of cutoff value and correct handling of assay materials. A standardization program is needed to identify common standard sera and common measuring units.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Immunologi inom det medicinska området (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Immunology in the medical area (hsv//eng)

Nyckelord

Addison's disease
adrenal antibodies
autoimmunity
diagnosis
RIA
standardization
Addison's disease

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy