SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Toksvig Larsen Sören)
 

Sökning: WFRF:(Toksvig Larsen Sören) > A randomised RSA st...

A randomised RSA study of Peri-Apatitetrade mark HA coating of a total knee prosthesis.

Hansson, Ulrik (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
Ryd, Leif (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
Toksvig-Larsen, Sören (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
Elsevier BV, 2008
2008
Engelska.
Ingår i: Knee. - : Elsevier BV. - 1873-5800. ; 15, s. 211-216
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: In total knee replacement, sound early fixation of the prosthesis is crucial for achieving a good long-term result and for minimising the risk of loosening. Various types of prosthetic material, different surface textures and shapes and the incorporation of screws or pegs have been used to achieve good fixation, particularly in the uncemented knee. Hydroxyapatite (HA) coating of prosthetic joint components is another technique used to enhance early stability and so to improve the longevity of the prosthesis-bone fixation. HA ceramic coatings are mostly plasma sprayed onto the fixation surface of the implant. Plasma spraying is largely a 'line of sight' technique and as such there are difficulties involved when covering three-dimensional planes, such as porous beaded fixation surfaces typically found on several knee prostheses. The objective of this study was to assess the clinical performance of the solution-deposited HA coating, Peri-Apatitetrade mark , with regard to its ability to stimulate an endurable and stable implant fixation. PATIENTS AND METHODS: We randomised 60 patients into two groups; one group received the porous coated prosthesis with solution-deposited HA, and the other group received a prosthesis without HA. Radiostereometric examination was used as the primary tool for measuring migration in the prosthetic components. RESULTS: There was a lower incidence of early subsidence in the Peri-Apatitetrade mark group. At 24 months there were no differences in clinical scorings or maximal total point motion. CONCLUSION: Addition of solution-deposited HA coating appears to provide better early stable fixation in a porous coated knee prosthesis.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Knee (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hansson, Ulrik
Ryd, Leif
Toksvig-Larsen, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Knee
The Knee
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy