SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Strand Sven Erik)
 

Sökning: WFRF:(Strand Sven Erik) > (1977-1979) > The dual photopeak-...

The dual photopeak-area method applied to scintillation camera measurements of effective depth and activity of in vivo 123I-distributions

Strand, Sven Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Persson, Bertil R.R. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
1977
1977
Engelska 8 s.
Ingår i: European Journal Of Nuclear Medicine. - 0340-6997. ; 2:2, s. 121-128
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Attenuation curves and photopeak ratios of 159 keV and 28 keV phtons emitted in the decay of 123I have been studied using a scintillation camera equipped with an extra ADC for recording the pulse height distribution of the energy signal. Cavities of various sizes containing 123I-solution were placed at different depths in a water phantom in order to vary the effective depth, i.e., the thickness of attenuating material above the cavity plus the distance to the centre of activity in the cavity. The centre of activity varies with the distribution of activity in the cavity, size of cavity, and the effective attenuation coefficient derived from the attenuation curves. From the photopeak ratio an average effective depth is determined which can be used for calculating the attenuation correction factor. The dual photopeak ratio has been used in clinical evaluation of thyroid 123I uptake measurements where effective depths ranging from 21 to 43 mm were obtained for the activity in the thyroid. Applications of the photopeak ratio method for renography with 123I-hippuran and blood flow studies using 133Xe or 127Xe and studies with many other radionuclides are also discussed.

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Strand, Sven Eri ...
Persson, Bertil ...
Artiklar i publikationen
European Journal ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy