SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Reumatologi och inflammation)
 

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Reumatologi och inflammation) > (1980-1989) > Measurement of oxyg...

Measurement of oxygen and carbon dioxide partial pressures in synovial fluid after tonometry

Geborek, Pierre (författare)
Lund University,Lunds universitet,Reumatologi och molekylär skelettbiologi,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Rheumatology,Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
Lindoff, B (författare)
Valind, Sven (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
 (creator_code:org_t)
1988
1988
Engelska.
Ingår i: Clinical Physiology. - 1365-2281. ; 8:4, s. 427-432
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A commercially available gas analyser was used to measure tension of oxygen (PO2) and carbon dioxide (PCO2) in synovial fluid samples after tonometry. Measured values of PCO2 were close to the expected (median difference 0.2 kPa, range -0.4 to 0.4) within the analysed concentration range of 4-10 kPa. No consistent difference between measured and expected values of PO2 were found for oxygen in the range 3-11 kPa (median difference 0.1 kPa, range -0.3 to 1.2). For oxygen tensions below 3 kPa, however, the measured values invariably overestimated the actual PO2, the errors ranging from 0.3 to 1.9 kPa, median 1.1. The importance of proper handling of samples was investigated and storage for 1 h at 0 degrees C in plastic syringes resulted in elevation of the PO2 levels measured (range of elevation 0.2 to 3.6 kPa, median 1.15), whilst no significant differences were found when stored in glass syringes. Within the limits stated, commercially available gas analysers may thus be used to investigate these parameters related to local tissue metabolism in effusive joint conditions.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)

Nyckelord

gas tension
oxygen
carbon dioxide
partial pressure
synovial fluid
tonometry

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Geborek, Pierre
Lindoff, B
Valind, Sven
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Reumatologi och ...
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy