SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:21f8b7e0-18c6-423d-8aed-abefca15ad11"
 

Search: id:"swepub:oai:lup.lub.lu.se:21f8b7e0-18c6-423d-8aed-abefca15ad11" > Artifact reduction ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Bakic, Predrag R.University of Pennsylvania (author)

Artifact reduction in simultaneous tomosynthesis and mechanical imaging of the breast

  • Article/chapterEnglish2019

Publisher, publication year, extent ...

  • SPIE,2019

Numbers

  • LIBRIS-ID:oai:lup.lub.lu.se:21f8b7e0-18c6-423d-8aed-abefca15ad11
  • https://lup.lub.lu.se/record/21f8b7e0-18c6-423d-8aed-abefca15ad11URI
  • https://doi.org/10.1117/12.2512743DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:kon swepub-publicationtype
  • Subject category:ref swepub-contenttype

Notes

  • Mechanical imaging (MI) uses a pressure sensor array to estimate the stiffness of lesions. Recent clinical studies have suggested that MI combined with digital mammography may reduce false positive findings and negative biopsies by over 30%. Digital breast tomosynthesis (DBT) has been adopted progressively in cancer screening. The tomographic nature of DBT improves lesion visibility by reducing tissue overlap in reconstructed images. For maximum benefit, DBT and MI data should be acquired simultaneously; however, that arrangement produces visible artifacts in DBT images due to the presence of the MI sensor array. We propose a method for reducing artifacts during the DBT image reconstruction. We modified the parameters of a commercial DBT reconstruction engine and investigated the conspicuity of artifacts in the resultant images produced with different sensor orientations. The method was evaluated using a physical anthropomorphic phantom imaged on top of the sensor. Visual assessment showed a reduction of artifacts. In a quantitative test, we calculated the artifact spread function (ASF), and compared the ratio of the mean ASF values between the proposed and conventional reconstruction (termed ASF ratio, RASF). We obtained a mean RASF of 2.74, averaged between two analyzed sensor orientations (45° and 90°). The performance varied with the orientation and the type of sensor structures causing the artifacts. RASF for wide connection lines was larger at 45° than at 90° (5.15 vs. 1.00, respectively), while for metallic contacts RASF was larger at 90° than at 45° (3.31 vs. 2.21, respectively). Future work will include a detailed quantitative assessment, and further method optimization in virtual clinical trials.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Dustler, MagnusLund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine(Swepub:lu)med-mdu (author)
  • Förnvik, DanielLund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine(Swepub:lu)med-dif (author)
  • Timberg, PontusLund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine(Swepub:lu)po6304ti (author)
  • Ng, SusanReal Time Tomography, LLC (author)
  • Maidment, Andrew D.A.University of Pennsylvania (author)
  • Zackrisson, SophiaLund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups(Swepub:lu)smi-sza (author)
  • Tingberg, AndersLund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine(Swepub:lu)rfa-ati (author)
  • Bosmans, Hilde (editor)
  • Chen, Guang-Hong (editor)
  • Schmidt, Taly Gilat (editor)
  • University of PennsylvaniaDiagnostisk radiologi, Lund (creator_code:org_t)

Related titles

  • In:Medical Imaging 2019 : Physics of Medical Imaging - Physics of Medical Imaging: SPIE109489781510625433

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view