SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ménard Sylvain)
 

Sökning: WFRF:(Ménard Sylvain) > Acoustical Treatmen...

Acoustical Treatments on Ventilation Ducts through Walls : Experimental Results and Novel Models

Nilsson, Erik (författare)
University of Quebec at Chicoutimi
Ménard, Sylvain (författare)
University of Quebec at Chicoutimi
Hagberg, Delphine Bard (författare)
Lund University,Lunds universitet,Teknisk akustik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Engineering Acoustics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Vardaxis, Nikolaos Georgios (författare)
Lund University,Lunds universitet,Teknisk akustik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Engineering Acoustics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2022-03-18
2022
Engelska.
Ingår i: Acoustics. - : MDPI AG. - 2624-599X. ; 4:1, s. 276-296
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Sound reduction is complex to estimate for acoustical treatments on ventilation ducts through walls. Various acoustical treatments are available for ventilation ducts, including internal lining (absorption along the inner perimeter), external lagging (external sound insulation), silencer, and suspended ceilings. Previous studies have examined how silencers and the internal lining affect the sound transmission of ventilation ducts. However, there are few theories to predict the effect of external lagging in combination with ventilation ducts and how the total sound reduction is affected. This article aims to investigate different acoustical treatments and develop theoretical models when external lagging with stone wool is used to reduce flanking sound transmission via the surface area of ventilation ducts. Theoretical models are developed for external lagging and compared with measurement data. Measurements and theory are generally in good agreement over the third-octave band range of 100–5000 Hz. The developed models clarify that the distance closest to the wall has the main impact on sound reduction for a combined system with a wall and a ventilation duct. Suspended ceilings and silencers are found to be enough as acoustical treatments for certain combinations of ventilation ducts and walls. However, external lagging seems to be the only effective solution in offices and schools when a large ventilation duct passes through a wall with high sound reduction.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Nyckelord

breakin
breakout
external lagging
flanking sound transmission
sound reduction
ventilation duct

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Acoustics (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Nilsson, Erik
Ménard, Sylvain
Hagberg, Delphin ...
Vardaxis, Nikola ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Strömningsmekani ...
Artiklar i publikationen
Acoustics
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy