SwePub
Sök i LIBRIS databas

  Utökad sökning

AMNE:(ENGINEERING AND TECHNOLOGY Other Engineering and Technologies Food Engineering)
 

Sökning: AMNE:(ENGINEERING AND TECHNOLOGY Other Engineering and Technologies Food Engineering) > (2005-2009) > Evaluation of new m...

Evaluation of new methods and measuring systems for characterisation of flow behaviour of complex foods

Roos, H (författare)
Bolmstedt, Ulf (författare)
Lund University,Lunds universitet,Livsmedelsteknik,Avdelningen för livsmedel och läkemedel,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Food Technology, Engineering and Nutrition,Division of Food and Pharma,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Axelsson, Anders (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2006
2006
Engelska.
Ingår i: Applied Rheology. - 1430-6395. ; 16:1, s. 19-25
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Conventional methods often impose difficulties when measuring the viscosity of fluids containing particles or fibres, e.g. tomato paste or fruit preparations, mainly due to the narrow gaps of the viscometer. In order to solve these problems different geometries have been developed, e.g. different mixer systems and wide gap double concentric cylinders. However, these can not be evaluated assuming a constant shear rate throughout the fluid. In this study, three different kinds of mixer systems have been studied; a small and a large paddle and a helix. For the mixer systems an average shear rate must be determined and a quotient between torque and shear stress must be found. in addition, a wide gap double concentric cylinder (DCC) was examined and evaluated using two different methods. When evaluating the mixer systems a method based on the Couette analogy has been used successfully for a number of complex fluids, including prepared sauces and fruit samples containing particles of different size. The DCC has been evaluated using a numerical as well as an approximate method, both giving results of good accuracy. All systems had the limitation that no consistent results were obtained for tomato paste. However, when starch was added to the diluted tomato paste dispersion, satisfying results were once again obtained.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik -- Livsmedelsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies -- Food Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

food dispersions
tomato paste
rheology
food
double concentric cylinder
Couette analogy
mixer viscometer

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Roos, H
Bolmstedt, Ulf
Axelsson, Anders
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Annan teknik
och Livsmedelsteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
Artiklar i publikationen
Applied Rheology
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy