SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Oskarsson Gylfi)
 

Sökning: WFRF:(Oskarsson Gylfi) > Coronary flow reser...

Coronary flow reserve in the newborn lamb: An intracoronary Doppler guide wire study

Oskarsson, Gylfi (författare)
Pesonen, Erkki (författare)
Lund University,Lunds universitet,Pediatrik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Paediatrics (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Gudmundsson, Saemundur (författare)
Lund University,Lunds universitet,Urogynekologi och reproduktionsfarmakologi,Forskargrupper vid Lunds universitet,Urogynaecology and Reproductive Pharmacology,Lund University Research Groups
visa fler...
Ingimarsson, Jonas (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Forskargrupper vid Lunds universitet,Anaesthesiology and Intensive Care Medicine,Lund University Research Groups
Sandström, Staffan (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Werner, Olof (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2004
2004
Engelska.
Ingår i: Pediatric Research. - 1530-0447. ; 55:2, s. 205-210
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Recent studies indicate a severely reduced coronary flow reserve (CFR) in neonates with congenital heart disease. The significance of these studies remains debatable, as the ability of the anatomically normal neonatal heart to increase coronary flow is currently unknown. This study was designed to establish normal values for CFR in newborns after administration of adenosine [pharmacologic CFR (pCFR)] and as induced by acute hypoxemia (reactive CFR). Thirteen mechanically ventilated newborn lambs were studied. Coronary flow velocities were measured in the proximal left anterior descending coronary artery before and after adenosine injection (140 and 280 mug/kg i.v.) using an intracoronary 0.014-in Doppler flow-wire. Measurements were made at normal oxygen saturation (Sao(2)) and during progressive hypoxemia induced by lowering the fraction of inspired oxygen. CFR was defined as the ratio of hyperemic to basal average peak flow velocity. In a hemodynamically stable situation with normal Sao(2,) pCFR was 3.0 +/- 0.5. pCFR decreased with increasing hypoxemia. Regression analysis showed a linear relation between Sao(2) and pCFR (R = 0.86, p < 0.0001). Reactive CFR obtained at severe hypoxemia (Sao(2) <30%) was 4.2 +/- 0.8, and no significant further increase in coronary flow velocity occurred by administration of adenosine. Newborn lambs have a similar capacity to increase coronary flow in response to both pharmacologic and reactive stimuli as older subjects. Administration of adenosine does not reveal the full capacity of the newborn coronary circulation to increase flow, however, as the flow increase caused by severe hypoxemia is significantly more pronounced.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy