SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Fernandes Tavares Pedro)
 

Sökning: WFRF:(Fernandes Tavares Pedro) > The MAX IV storage ...

The MAX IV storage ring project.

Fernandes Tavares, Pedro (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Leemann, Simon (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Sjöström, Magnus (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
visa fler...
Andersson, Åke (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 21:Pt 5, s. 862-877
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The MAX IV facility, currently under construction in Lund, Sweden, features two electron storage rings operated at 3 GeV and 1.5 GeV and optimized for the hard X-ray and soft X-ray/VUV spectral ranges, respectively. A 3 GeV linear accelerator serves as a full-energy injector into both rings as well as a driver for a short-pulse facility, in which undulators produce X-ray pulses as short as 100 fs. The 3 GeV ring employs a multibend achromat (MBA) lattice to achieve, in a relatively short circumference of 528 m, a bare lattice emittance of 0.33 nm rad, which reduces to 0.2 nm rad as insertion devices are added. The engineering implementation of the MBA lattice raises several technological problems. The large number of strong magnets per achromat calls for a compact design featuring small-gap combined-function magnets grouped into cells and sharing a common iron yoke. The small apertures lead to a low-conductance vacuum chamber design that relies on the chamber itself as a distributed copper absorber for the heat deposited by synchrotron radiation, while non-evaporable getter (NEG) coating provides for reduced photodesorption yields and distributed pumping. Finally, a low main frequency (100 MHz) is chosen for the RF system yielding long bunches, which are further elongated by passively operated third-harmonic Landau cavities, thus alleviating collective effects, both coherent (e.g. resistive wall instabilities) and incoherent (intrabeam scattering). In this paper, we focus on the MAX IV 3 GeV ring and present the lattice design as well as the engineering solutions to the challenges inherent to such a design. As the first realisation of a light source based on the MBA concept, the MAX IV 3 GeV ring offers an opportunity for validation of concepts that are likely to be essential ingredients of future diffraction-limited light sources.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Fernandes Tavare ...
Leemann, Simon
Sjöström, Magnus
Andersson, Åke
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Acceleratorfysik ...
Artiklar i publikationen
Journal of Synch ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy