Sökning: L773:0142 9612 OR L773:1878 5905 >
Protein adsorption ...
Protein adsorption of poly(ether urethane) surfaces modified by amphiphilic and hydrophilic polymers
-
- Wesslén, Bengt (författare)
- Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
Kober, Maria (författare)
-
Freij-Larsson, Christina (författare)
-
visa fler...
-
- Ljungh, Åsa (författare)
- Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
-
Paulsson, Marianne (författare)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 1994
- 1994
- Engelska.
-
Ingår i: Biomaterials. - : Elsevier BV. - 1878-5905 .- 0142-9612. ; 15:4, s. 278-284
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A commercial biomedical poly(ether urethane), Pellethane 2363-80AE, was surface modified through the use of amphiphilic polymeric additives, and through surface grafting with poly(ethylene glycol), PEG. Two different amphiphilic polymers, Polymer C and Pluronic PE9400, were used as additives. Polymer C, a segmented polyurethane, was prepared from PEG1500, 4,4'-diphenylmethane diisocyanate and a C-16-C18 monoglyceride chain extender. Pluronic PE9400 is a propylene oxide-ethylene oxide tri-block co-polymer obtained from BASF. Adsorption of human albumin and fibrinogen to the modified surfaces was studied by means of radiolabelled proteins. By contact angle measurements and X-ray photoelectron spectra the amphiphilic polymers were shown to accumulate at the polyurethane surfaces. Adsorption of fibrinogen, in particular, was significantly reduced by the amphiphilic additives to levels similar to those obtained for Pellethane surfaces grafted with PEG 20000. In vitro clotting times for citrate-buffered blood in contact with the amphiphilic surfaces increased as compared with the unmodified ones.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Industriell bioteknik -- Bioteknisk apparatteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Industrial Biotechnology -- Bioengineering Equipment (hsv//eng)
Nyckelord
- amphiphilic polymers
- surface modification
- Protein adsorption
- polymer grafting
- poly(ethylene glycol)
- polyurethane
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas