SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1878 5905 OR L773:0142 9612
 

Sökning: L773:1878 5905 OR L773:0142 9612 > Protein adsorption ...

Protein adsorption of poly(ether urethane) surfaces modified by amphiphilic and hydrophilic polymers

Wesslén, Bengt (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Kober, Maria (författare)
Freij-Larsson, Christina (författare)
visa fler...
Ljungh, Åsa (författare)
Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
Paulsson, Marianne (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 1994
1994
Engelska.
Ingår i: Biomaterials. - : Elsevier BV. - 1878-5905 .- 0142-9612. ; 15:4, s. 278-284
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A commercial biomedical poly(ether urethane), Pellethane 2363-80AE, was surface modified through the use of amphiphilic polymeric additives, and through surface grafting with poly(ethylene glycol), PEG. Two different amphiphilic polymers, Polymer C and Pluronic PE9400, were used as additives. Polymer C, a segmented polyurethane, was prepared from PEG1500, 4,4'-diphenylmethane diisocyanate and a C-16-C18 monoglyceride chain extender. Pluronic PE9400 is a propylene oxide-ethylene oxide tri-block co-polymer obtained from BASF. Adsorption of human albumin and fibrinogen to the modified surfaces was studied by means of radiolabelled proteins. By contact angle measurements and X-ray photoelectron spectra the amphiphilic polymers were shown to accumulate at the polyurethane surfaces. Adsorption of fibrinogen, in particular, was significantly reduced by the amphiphilic additives to levels similar to those obtained for Pellethane surfaces grafted with PEG 20000. In vitro clotting times for citrate-buffered blood in contact with the amphiphilic surfaces increased as compared with the unmodified ones.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik -- Bioteknisk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology -- Bioengineering Equipment (hsv//eng)

Nyckelord

amphiphilic polymers
surface modification
Protein adsorption
polymer grafting
poly(ethylene glycol)
polyurethane

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy