Variability in diagnosis of clue cells, lactobacillary grading and white blood cells in vaginal wet smears with conventional bright light and phase contrast microscopy

Donders, G. G. G. (författare)
University Hospital Gasthuisberg
Larsson, Per-Göran (författare)
Linköpings universitet,Genus och medicin,Hälsouniversitetet
Platz-Christensen, J. J. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences,University of Gothenburg
visa fler...
Hallen, A. (författare)
Uppsala universitet,Dermatologi och venereologi,Uppsala University
van der Meijden, W. (författare)
University of Rotterdam
Wölner-Hanssen, Pål (författare)
Lund University,Lunds universitet,Obstetrik och gynekologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Obstetrics and Gynaecology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: European Journal of Obstetrics, Gynecology, and Reproductive Biology. - : Elsevier BV. - 0301-2115 .- 1872-7654. ; 145:1, s. 109-112
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: Study the reproducibility of wet smear interpretation of clue cells, lactobacillary grades and leukocyte dominance with conventional bright light and phase contrast microscopy. Study design: Sets of vaginal specimens were taken from unselected consecutive women attending an outpatient gynaecology clinic. Air-dried vaginal fluid on a microscope slide was rehydrated with isotonic saline before examination by six independent international investigators. Some investigators initially used a conventional bright light microscope, followed by phase contrast technique. Results: Using phase contrast microscopy, an excellent inter-observer agreement was obtained among all investigators for clue cells detection (Kappa values from 0.69 to 0.94) and lactobacillary grades (Kappa 0.73-0.93). When conventional light microscopes were used, poor agreement was obtained for these criteria (Kappa index 0.37-0.72 and 0.80, respectively), but switching to phase contrast microscopy by the same investigators, improved Kappa to 0.83-0.85 and 0.88, respectively. The inter-observer agreement for estimation of the leukocyte/epithelial cell ratio (Kappa index 0.17-0.67) was poor, irrespective of the type of microscopy applied. Intra-observer agreement of clue cell detection and lactobacillary grading was also found to be excellent if phase contrast microscopy was used (Kappa 0.87-0.93), and poor with conventional bright light microscopy (Kappa 0.45-0.66). Conclusion: Clue cells and the lactobacillary grades are reliably identified by phase contrast microscopy in wet smears, with excellent intra- and inter-observer reproducibility agreement, and better than when simple bright light microscopy was used. Evaluation of leukocyte grading, on the other hand, was inconsistent among the different microscopists, irrespective of the type of microscope used. We propose to grade the leukocytes in a different way than searching for leukocyte dominance over epithelial cells, namely by counting them per high power field and per epithelial cell. (c) 2009 Elsevier Ireland Ltd. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)
NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)

Nyckelord

Leukocytes
Abnormal vaginal flora
vaginitis
Aerobic
Lactobacillary grades
Bacterial vaginosis
Clue cells
Wet smear
Phase
contrast microscopy
bacterial vaginosis
gram stain
flora
Bacterial vaginosis
MEDICINE

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy