SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1532 8430 OR L773:0022 0736
 

Sökning: L773:1532 8430 OR L773:0022 0736 > DeltaT50 - a new me...

DeltaT50 - a new method to assess temporal ventricular repolarization variability

Abrahamsson, Christina (författare)
Dota, Corina (författare)
Skallefell, Bo (författare)
visa fler...
Carlsson, Leif (författare)
Halawani, Dunia (författare)
Frison, Lars (författare)
Berggren, Anders (författare)
Edvardsson, Nils, 1942 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Duker, Göran (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2011
2011
Engelska.
Ingår i: Journal of Electrocardiology. - : Elsevier BV. - 1532-8430 .- 0022-0736. ; 44:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Increased beat-to-beat variability in cardiac repolarization time is a tentative risk marker of drug-induced torsades de pointes. We developed a new, automatic method based on the temporal variability of the T-wave down slope to assess this variability. Method and Results Leads V1 to V6 of resting electrocardiograms were recorded in 42 healthy subjects (18-68 years, 22 men). The temporal variability at 50% of the T-wave down slope, deltaT50 (1.5 ± 0.41 milliseconds; range, 0.86-2.66 milliseconds), was measured with an accuracy of 1 millisecond on at least 9 pairs of electrocardiogram complexes with a signal-to-noise ratio more than 10 and changes in the R-R interval less than 150 milliseconds. The correlation between repeated measurements of deltaT50 was high. DeltaT50 was measured without corrections for age, sex, heart rate, T-wave amplitude, signal-to-noise ratio, R-R variability, and QTcF because none of these factors explained more than 4% of the within-subject deltaT50 variability. Conclusion The beat-to-beat repolarization variability was measured with high fidelity with the deltaT50 method and was a robust measure in healthy volunteers.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Beat-to-beat
QT variability
Repolarization instability
Automatic analysis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy