SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0169 2607
 

Sökning: L773:0169 2607 > A Monte Carlo progr...

A Monte Carlo program for the simulation of scintillation camera characteristics

Ljungberg, Michael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Strand, Sven-Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
Elsevier BV, 1989
1989
Engelska.
Ingår i: Computer Methods and Programs in Biomedicine. - : Elsevier BV. - 0169-2607. ; 29:4, s. 257-272
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • There is a need for mathematical modelling for the evaluation of important parameters for photon imaging systems. A Monte Carlo program which simulates medical imaging nuclear detectors has been developed. Different materials can be chosen for the detector, a cover and a phantom. Cylindrical, spherical, rectangular and more complex phantom and source shapes can be simulated. Photoelectric, incoherent, coherent interactions and pair production are simulated. Different detector parameters, e.g. the energy pulse-height distribution and pulse pile-up due to finite decay time of the scintillation light emission, can be calculated. An energy resolution of the system is simulated by convolving the energy imparted with an energy-dependent Gaussian function. An image matrix of the centroid of the events in the detector can be simulated. Simulation of different collimators permits studies of spatial resolution and sensitivity. Comparisons of our results with experimental data and other published results have shown good agreement. The usefulness of the Monte Carlo code for the accurately simulation of important parameters in scintillation camera systems, stationary as well as SPECT (single-photon emission computed tomography) systems, has been demonstrated.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Imaging
Pile-up
Photon transport
Scatter simulation
Monte Carlo
SPECT
Spectrum
Scintillation camera

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ljungberg, Micha ...
Strand, Sven-Eri ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Computer Methods ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy