SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lindgren Arne)
 

Sökning: WFRF:(Lindgren Arne) > (2000-2004) > Perfusion-related p...

Perfusion-related parameters in intravoxel incoherent motion MR imaging compared with CBV and CBF measured by dynamic susceptibility-contrast MR technique

Wirestam, Ronnie (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Borg, M (författare)
Brockstedt, Sara (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Lindgren, Arne (författare)
Lund University,Lunds universitet,Neurologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Holtås, Stig (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ståhlberg, Freddy (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medicinsk strålningsfysik, Lund,Institutionen för kliniska vetenskaper, Lund,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Medical Radiation Physics, Lund,Department of Clinical Sciences, Lund
visa färre...
 (creator_code:org_t)
2016-08-30
2001
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 42:2, s. 123-128
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: Perfusion-related parameters obtained by intravoxel incoherent motion (IVIM) MR imaging (MRI) were compared with cerebral blood volume and flow (CBV and CBF), retrieved by dynamic susceptibility-contrast (DSC) MRI. MATERIAL AND METHODS: Twenty-eight volunteers (average age 68.5 years) were investigated. Spin-echo echo-planar imaging with IVIM-encoding gradients was employed (36 different b values, 0-1200 s/mm2). The perfusion fraction and the pseudo-diffusion coefficient were calculated for regions in thalamus gray matter and frontal white matter, using asymptotic and full fitting. In DSC-MRI, a Gd-DTPA-BMA contrast-agent bolus was monitored using simultaneous-dual FLASH. Deconvolution of the measured tissue concentration-versus-time curve with an arterial input function from the carotid artery was applied, and maps of CBV and CBF were calculated. RESULTS: The correlation between the perfusion fraction and CBV was r=0.56 (p<0.0000006) using asymptotic fitting, and r=0.35 (p<0.0004) when full fitting was applied. Average CBF was 41.5 ml/(min 100 g), to be compared with the IVIM-based value of 63.6 ml/(min 100 g), obtained from the median value of the pseudo-diffusion coefficient in combination with assumptions about capillary network structure. CONCLUSION: The IVIM concept provided results that agreed reasonably with conventional CBV and CBF. The non-linear fitting to noisy signal data was problematic, in accordance with previously presented simulations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Brain
Cerebral Circulation
Blood Volume Determination
Diffusion
Mr Imaging

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy