SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:3d2c9456-ae30-4fc5-bcf5-bce4e3df5779"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:3d2c9456-ae30-4fc5-bcf5-bce4e3df5779" > Free and complexed ...

  • Pettersson, KUniversity of Turku (författare)

Free and complexed prostate-specific antigen (PSA) : in vitro stability, epitope map, and development of immunofluorometric assays for specific and sensitive detection of free PSA and PSA-alpha 1-antichymotrypsin complex

  • Artikel/kapitelEngelska1995

Förlag, utgivningsår, omfång ...

  • 1995
  • 9 s.

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:3d2c9456-ae30-4fc5-bcf5-bce4e3df5779
  • https://lup.lub.lu.se/record/3d2c9456-ae30-4fc5-bcf5-bce4e3df5779URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • Generation of 15 monoclonal antibodies (MAbs) allowed construction of epitope maps and specific two-site immunofluorometric assays for free prostate-specific antigen (PSA) and PSA complexed with alpha 1-antichymotrypsin (ACT). Close correlation of PSA concentrations obtained with the use of different assays of free PSA suggested extensive similarity in immunodetection of free PSA in serum. Assays of the PSA-ACT complex overestimated the concentration of PSA-ACT in serum because of nonspecific adsorbance of ACT or cathepsin G-complexed ACT to the solid phase. This interference was substantially decreased in the presence of heparin. In studying the stability of purified PSA and PSA-ACT complexes formed in vitro, we found that the free PSA was stable during storage for 4 weeks at 35 degrees C, whereas PSA-ACT complexes largely dissociated in these conditions. The instability of PSA-ACT complexes was counteracted by storage at low temperatures, by adjusting the pH of the storage buffer between 6.8 and 7.4, and through addition of 100-1000-fold molar excess of native ACT. The ease of calibration and the accuracy of free PSA assays in comparison with assays of the PSA-ACT complex suggest that measurements of free to total PSA most accurately reflect the inverse of the proportion of PSA complexed to ACT in serum.

Ämnesord och genrebeteckningar

  • Adsorption
  • Animals
  • Antibodies, Monoclonal
  • Cathepsin G
  • Cathepsins/blood
  • Drug Stability
  • Epitope Mapping
  • False Positive Reactions
  • Fluoroimmunoassay/methods
  • Humans
  • Male
  • Mice
  • Mice, Inbred BALB C
  • Prostate-Specific Antigen/blood
  • Sensitivity and Specificity
  • Serine Endopeptidases
  • alpha 1-Antichymotrypsin/blood

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Piironen, TUniversity of Turku (författare)
  • Seppälä, MUniversity of Turku (författare)
  • Liukkonen, L (författare)
  • Christensson, ALund University,Lunds universitet,Internmedicin - epidemiologi,Forskargrupper vid Lunds universitet,Internal Medicine - Epidemiology,Lund University Research Groups,Skåne University Hospital(Swepub:lu)medf-ach (författare)
  • Matikainen, M TUniversity of Turku (författare)
  • Suonpää, M (författare)
  • Lövgren, TUniversity of Turku (författare)
  • Lilja, HLund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups(Swepub:lu)klke-hli (författare)
  • University of TurkuInternmedicin - epidemiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Clinical Chemistry41:10, s. 8-14800009-9147

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy