SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0002 9270 OR L773:1572 0241
 

Sökning: L773:0002 9270 OR L773:1572 0241 > Optimal Thresholds ...

Optimal Thresholds and Discriminatory Power of 48-h Wireless Esophageal pH Monitoring in the Diagnosisof GERD.

Wenner, Jörgen (författare)
Lund University,Lunds universitet,Kirurgi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Surgery (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Johansson, Jan (författare)
Lund University,Lunds universitet,Kirurgi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Surgery (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Johnsson, Folke (författare)
Lund University,Lunds universitet,Kirurgi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Surgery (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Öberg, Stefan (författare)
Lund University,Lunds universitet,Kirurgi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Surgery (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
Ovid Technologies (Wolters Kluwer Health), 2007
2007
Engelska.
Ingår i: American Journal of Gastroenterology. - : Ovid Technologies (Wolters Kluwer Health). - 1572-0241 .- 0002-9270. ; 102:9, s. 1862-1869
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: The discriminative power of 48-h wireless esophageal pH monitoring in the diagnosis of gastroesophageal reflux disease has not been clearly demonstrated, and the cutoff level for esophageal acid exposure generating the optimal sensitivity and specificity is unknown. SUBJECTS AND Patients with typical reflux symptoms and a distinct response to acid suppressive medication METHODS: underwent upper GI endoscopy followed by 48-h wireless esophageal pH studies with the pH electrode placed 6 cm above the squamocolumnar junction. The results were compared to those obtained in 55 healthy controls. Sensitivity, specificity, and thresholds for esophageal acid exposure were analyzed using receiver operating characteristic (ROC) curves. RESULTS: The patient population consisted of 64 patients, 25 women and 39 men, with a median age of 48 yr. Analysis of the area under the ROC curve showed that, for all patients as well as for subgroups of patients with (N = 33) and without (N = 31) esophagitis, the total percent time with pH < 4 for the 48-h study period was the best parameter to discriminate patients from controls. Analysis of acid exposure for day 1, day 2, or using the day with the highest acid exposure did not improve the diagnostic accuracy. A test specificity in the range of 90-95% resulted in a cutoff level of 3.6-4.4% of the total time with pH < 4 for the 48-h period. This threshold generated a test sensitivity of 59-64% in all patients, 76-79% for patients with esophagitis and 42-48% in patients with no esophagitis. CONCLUSIONS: The total percentage of time that esophageal pH was less than 4 for the entire 48-h study period was the parameter that best discriminated patients with typical reflux symptoms from healthy controls, and to achieve a specificity of 90-95% a cutoff level of 4% is recommended. The low sensitivity of wireless pH recording in patients without erosive esophagitis substantially reduces the clinical value of the test.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Gastroenterologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Gastroenterology and Hepatology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wenner, Jörgen
Johansson, Jan
Johnsson, Folke
Öberg, Stefan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Gastroenterologi
Artiklar i publikationen
American Journal ...