Search: L773:1522 2594 OR L773:0740 3194
> (2020-2024) >
Echo time dependenc...
Echo time dependence of biexponential and triexponential intravoxel incoherent motion parameters in the liver
-
- Führes, Tobit (author)
- University Hospital Erlangen
-
- Riexinger, Andreas Julian (author)
- University Hospital Erlangen
-
- Loh, Martin (author)
- University Hospital Erlangen
-
show more...
-
- Martin, Jan (author)
- Lund University,Lunds universitet,Fysikalisk kemi,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Physical Chemistry,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
- Wetscherek, Andreas (author)
- Royal Marsden NHS Foundation Trust
-
- Kuder, Tristan Anselm (author)
- German Cancer Research Centre
-
- Uder, Michael (author)
- University Hospital Erlangen
-
- Hensel, Bernhard (author)
- Friedrich-Alexander University Erlangen-Nürnberg
-
- Laun, Frederik Bernd (author)
- University Hospital Erlangen
-
show less...
-
(creator_code:org_t)
- 2021-08-28
- 2022
- English.
-
In: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 87:2, s. 859-871
- Related links:
-
http://dx.doi.org/10... (free)
-
show more...
-
https://onlinelibrar...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Purpose: Intravoxel incoherent motion (IVIM) studies are performed with different acquisition protocols. Comparing them requires knowledge of echo time (TE) dependencies. The TE-dependence of the biexponential perfusion fraction f is well-documented, unlike that of its triexponential counterparts f1 and f2 and the biexponential and triexponential pseudodiffusion coefficients D*, (Formula presented.), and (Formula presented.). The purpose was to investigate the TE-dependence of these parameters and to check whether the triexponential pseudodiffusion compartments are associated with arterial and venous blood. Methods: Fifteen healthy volunteers (19-58 y; mean: 24.7 y) underwent diffusion-weighted imaging of the abdomen with 24 b-values (0.2-800 s/mm2) at TEs of 45, 60, 75, and 90 ms. Regions of interest (ROIs) were manually drawn in the liver. One set of bi- and triexponential IVIM parameters per volunteer and TE was determined. The TE-dependence was assessed with the Kruskal-Wallis test. Results: TE-dependence was observed for f (P <.001), f1 (P =.001), and f2 (P <.001). Their median values at the four measured TEs were: f: 0.198/0.240/0.274/0.359, f1: 0.113/0.139/0.146/0.205, f2: 0.115/0.155/0.182/0.194. D, D*, (Formula presented.), and (Formula presented.) showed no significant TE-dependence. Their values were: diffusion coefficient D (10−4 mm2/s): 9.45/9.63/9.75/9.41, biexponential D* (10−2 mm2/s): 5.26/5.52/6.13/5.82, triexponential (Formula presented.) (10−2 mm2/s): 1.73/2.91/2.25/2.51, triexponential (Formula presented.) (mm2/s): 0.478/1.385/0.616/0.846. Conclusion: f1 and f2 show similar TE-dependence as f, ie, increase with rising TE; an effect that must be accounted for when comparing different studies. The diffusion and pseudodiffusion coefficients might be compared without TE correction. Because of the similar TE-dependence of f1 and f2, the triexponential pseudodiffusion compartments are most probably not associated to venous and arterial blood.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)