SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Thiele Holger)
 

Sökning: WFRF:(Thiele Holger) > ACURATE neo2 Transc...

ACURATE neo2 Transcatheter aortic valve implantation without balloon aortic valvuloplasty : direct ACURATE neo2

Elkoumy, Ahmed (författare)
Al-Azhar University,National University of Ireland Galway,Galway University Hospital
Rück, Andreas (författare)
Karolinska Institutet
Abdel-Wahab, Mohamed (författare)
Leipzig University
visa fler...
Thiele, Holger (författare)
Leipzig University
Rudolph, Tanja K. (författare)
Ruhr-University Bochum
Wolf, Alexander (författare)
Elisabeth Hospital Essen
Wambach, Jan Martin (författare)
Elisabeth Hospital Essen
De Backer, Ole (författare)
Copenhagen University Hospital
Sondergaard, Lars (författare)
Abbott Laboratories, US
Hengstenberg, Christian (författare)
Medical University of Vienna
Abdelshafy, Mahmoud (författare)
Galway University Hospital,National University of Ireland Galway,Al-Azhar University Hospital
Arsang-Jang, Shahram (författare)
CÚRAM, SFI Research Centre for Medical Device,National University of Ireland Galway,Galway University Hospital
Elzomor, Hesham (författare)
National University of Ireland Galway,Galway University Hospital
Laine, Mika (författare)
Helsinki University Central Hospital
Bjursten, Henrik (författare)
Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Skonsammare hjärtkirurgi,Forskargrupper vid Lunds universitet,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Less invasive cardiac surgery,Lund University Research Groups,Skåne University Hospital
Götberg, Matthias (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Wykrzykowska, Joanna J. (författare)
University of Groningen,University Medical Center Groningen
Mohamed, Sameh K. (författare)
National University of Ireland Galway,Galway University Hospital
Pellegrini, Costanza (författare)
Technical University of Munich
Rheude, Tobias (författare)
Technical University of Munich
Toggweiler, Stefan (författare)
Cantonal Hospital Lucerne
Saleh, Nawzad (författare)
Karolinska University Hospital
Meduri, Christopher U. (författare)
Karolinska University Hospital
Kim, Won Keun (författare)
Max Planck Institute for Heart and Lung Research
Soliman, Osama (författare)
Galway University Hospital,CÚRAM, SFI Research Centre for Medical Device,National University of Ireland Galway
visa färre...
 (creator_code:org_t)
2024
2024
Engelska 10 s.
Ingår i: International Journal of Cardiology. - 0167-5273 .- 1874-1754. ; 400
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. Aim: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. Methodology: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. Results: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. Conclusion: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

ACURATE neo2
Aortic valve calcification
Balloon aortic valvuloplasty
Self expandable valves
TAVI
Transcatheter aortic valve

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy