A New SITA Perimetric Threshold Testing Algorithm : Construction and a Multicenter Clinical Study

Heijl, Anders (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups,Skåne University Hospital
Patella, Vincent Michael (författare)
Carl Zeiss Meditec
Chong, Luke X. (författare)
University of California, Berkeley
visa fler...
Iwase, Aiko (författare)
Tajimi Iwase Eye Clinic
Leung, Christopher K. (författare)
Chinese University of Hong Kong
Tuulonen, Anja (författare)
Tampere University Hospital
Lee, Gary C. (författare)
Carl Zeiss Meditec
Callan, Thomas (författare)
Carl Zeiss Meditec
Bengtsson, Boel (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
Elsevier BV, 2019
2019
Engelska 12 s.
Ingår i: American Journal of Ophthalmology. - : Elsevier BV. - 0002-9394. ; 198, s. 154-165
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To describe a new time-saving threshold visual field–testing strategy—Swedish Interactive Thresholding Algorithm (SITA) Faster, which is intended to replace SITA Fast—and to report on a clinical evaluation of this new strategy. Design: Description and validity analysis for modifications applied to SITA Fast. Methods: Five centers tested 1 eye of each of 126 glaucoma and glaucoma suspect patients with SITA Faster, SITA Fast, and SITA Standard at each of 2 visits. Outcomes included test time, mean deviation, and the visual field index (VFI), significant test points in probability maps, and intertest threshold variability. Results: Mean (standard deviation) test times were 171.9 (45.3) seconds for SITA Faster, 247.0 (56.7) for SITA Fast, and 369.5 (64.5) for SITA Standard (P <.001). SITA Faster test times averaged 30.4 % shorter than SITA Fast and 53.5 % shorter than SITA Standard. Mean deviation was similar among all 3 tests.VFI did not differ between SITA Fast and SITA Faster tests, mean difference 0%, but VFI values were 1.2% lower with SITA Standard compared to both SITA Fast (P =.007) and SITA Faster (P =.002). A similar trend was seen with a slightly higher number of significant test points with SITA Standard than with SITA Fast and SITA Faster. All 3 tests had similar test–retest variability over the entire range of threshold values. Conclusions: SITA Faster saved considerable test time. SITA Faster and SITA Fast gave almost identical results. There were small differences between SITA Faster and SITA Standard, of the same character as previously shown for SITA Fast vs SITA Standard.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp