SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1745 3682
 

Sökning: L773:1745 3682 > Osteotomy of dorsal...

Osteotomy of dorsally displaced malunited fractures of the distal radius: no loss of radiographic correction during healing with a minimally invasive fixation technique and an injectable bone substitute.

Abramo, Antonio (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
Tägil, Magnus (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
Geijer, Mats (författare)
visa fler...
Kopylov, Philippe (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2009-07-08
2008
Engelska.
Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 79:2, s. 262-268
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND AND PURPOSE: Malunion after a distal radius fracture can be treated with an osteotomy of the distal radius. Often autologous iliac crest bone graft is used to fill the gap, but this is associated with donor site morbidity. Instead of bone graft, we have used a slow-resorbing bone substitute in combination with a minimally invasive fixation technique. PATIENTS AND METHODS: 25 consecutive patients with a dorsal malunion after a distal radius fracture underwent an osteotomy. A TriMed buttress pin and a radial pin plate were used for fixation, and Norian SRS as bone substitute. The patients were followed for a minimum of 1 year and range of motion, grip strength, DASH scores, and the radiographic correction were measured. RESULTS: Forearm rotation improved from 137 degrees to 155 degrees , flexion/extension from 102 degrees to 120 degrees , and radioul-nar deviation from 32 degrees to 43 degrees . Grip strength increased from 62% of the contralateral hand to 82%. DASH scores decreased from 36 to 23. Radiographically, all osteotomies but 1 healed and the radiographic correction achieved was consistent over the first year. INTERPRETATION: Osteotomy of the distal radius is effective in increasing motion and grip strength after a malunited distal radial fracture. Patient satisfaction is high and subjective results measured with DASH are good. Using a bone substitute, the operation can be performed as an outpatient procedure and donor-site pain avoided. No loss of the radiographic correction achieved was noted during osteotomy healing.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

Fractures
Radius Fractures: radiography
Calcium Phosphates: administration & dosage
Surgical Procedures
Osteotomy: methods
Radius Fractures: surgery
Internal: methods
Minimally Invasive: methods
Malunited: surgery
Fracture Fixation
Radius Fractures: physiopathology
Bone Substitutes: administration & dosage

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abramo, Antonio
Tägil, Magnus
Geijer, Mats
Kopylov, Philipp ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Acta Orthopaedic ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy