SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kopylov Uri)
 

Sökning: WFRF:(Kopylov Uri) > Clinical validity o...

Clinical validity of flexible spectral imaging color enhancement (FICE) in small-bowel capsule endoscopy : a systematic review and meta-analysis

Yung, Diana E (författare)
Royal Infirmary of Edinburgh
Boal Carvalho, Pedro (författare)
Hospital Senhora da Oliveira
Giannakou, Andry (författare)
Open University of Cyprus
visa fler...
Kopylov, Uri (författare)
Tel-Aviv University
Rosa, Bruno (författare)
Hospital Senhora da Oliveira
Rondonotti, Emanuele (författare)
Valduce Hospital
Toth, Ervin (författare)
Lund University,Lunds universitet,Gastroenterologi,Forskargrupper vid Lunds universitet,Gastroenterology,Lund University Research Groups,Skåne University Hospital
Koulaouzidis, Anastasios (författare)
Royal Infirmary of Edinburgh
Plevris, John N (författare)
Royal Infirmary of Edinburgh
visa färre...
 (creator_code:org_t)
2017-01-25
2017
Engelska.
Ingår i: Endoscopy. - : Georg Thieme Verlag KG. - 0013-726X .- 1438-8812. ; 49:3, s. 258-269
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • Patients and methods A comprehensive literature search was conducted. We measured pooled rate of lesion visualization improvement and improvement in lesion detection comparing FICE settings 1 – 3 and WLE, for angioectasias and ulcers/erosions. Pooled results were derived using the random-effects model because of high heterogeneity as measured by I 2. Repeated-measures analysis of variance (ANOVA) was used to measure differences in lesion detection between WLE and the three FICE modes. Results 13 studies were analyzed. All studies used the PillCam SB 1 and/or SB 2 devices. Most used experienced readers. Improvement in delineation had been investigated in 4 studies; in the 3 studies entered into the meta-analysis, using FICE setting 1, 89 % of angioectasias and 45 % of ulcer/erosions were considered to show improved delineation. For FICE settings 2 and 3, small proportions of images showed improved delineation. Heterogeneity of studies was high with I 2 > 90 % in 4/6 analyses. Lesion detection had been investigated in 10 studies; meta-analysis included 5 studies. Lesion detection did not differ significantly between any of the FICE modes and WLE. Conclusions Overall, the use of the three FICE modes did not significantly improve delineation or detection rate in SBCE. In pigmented lesions, FICE setting 1 performed better in lesion delineation and detection.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

for (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Endoscopy (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy