Impact of extruded mortar joints on the hygrothermal performance of brick veneer walls : A probabilistic study

Bayat Pour, Mohsen (författare)
Lund University,Lunds universitet,Avdelningen för Konstruktionsteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Structural Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Kahangi, Mohammad (författare)
Lund University,Lunds universitet,Avdelningen för Konstruktionsteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Structural Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2024
2024
Engelska 21 s.
Ingår i: Journal of Building Engineering. - 2352-7102. ; 94
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Mortar extrusion during bricklaying, resulting from suboptimal workmanship, may act as a bridge linking clay brick masonry claddings and adjacent layers (e.g., insulation or weather-resistant barriers), thereby, facilitating water penetration into the adjacent layer owing to wind-driven rain (WDR). Despite the significant effect of water penetration on the hygrothermal performance of building envelopes, a consensus regarding the incorporation of WDR-induced water penetration into moisture safety designs and analyses remains lacking. In 2022, Kahangi Shahreza et al. tested two distinct brick types with three diverse mortar joint profiles. Consequently, they proposed a water penetration criterion that can be implemented in hygrothermal analysis of clay brick masonry. The research in this paper combines the results of their study with probabilistic hygrothermal analysis by investigating the influence of extruded mortar on mould growth for a timber frame wall with brick masonry cladding. Two water penetration criteria, including ASHRAE and experimental study (ES) based on Kahangi Shahreza's study, were implemented while considering the different climatic conditions in Sweden. A metamodel, established using the random forests (RF) machine learning algorithm, serves as a tool for mould sensitivity analysis. The results of the probabilistic mould growth analysis revealed a congruence between the ASHRAE and ES criteria for locations with high WDR loads. However, in scenarios involving low WDR loads, the ASHRAE criterion yielded a higher maximum mould index than the ES criterion. In addition, the linear and non-linear mould sensitivity analyses demonstrated a positive correlation between the increase in the extruded mortar depth and elevated maximum mould indices. Nevertheless, the strength of this correlation is subject to alterations based on the WDR loads and selected water penetration criteria.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Mortar extrusion
Machine learning
Mould assessment
Clay brick masonry
Hygrothermal simulation

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bayat Pour, Mohs ...
Kahangi, Mohamma ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
Artiklar i publikationen
Journal of Build ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy