New improved method for 2D arterial wall movement measurements

Cinthio, Magnus (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Ahlgren, A (författare)
Jansson, Tomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Persson, Hans W (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Lindström, Kjell (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Proceedings of the International Federation for Medical & Biomedical Engineering. 13th Nordic Baltic Conference on Biomedical Engineering and Medical Physics. - 9173059102 ; , s. 117-118
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • We have recently reported that the inner layers of the arteries, the intima-media complex, of common carotid artery, move as much in the longitudinal direction as in the radial direction, during the cardiac cycle. In order to study this phenomenon we have developed a high-resolution ultrasonic method that can simultaneously record both the longitudinal and the radial movements of the arterial wall non-invasively in vivo. However, in young individuals with large movements and with thin intima-media complex it happens sometimes that the echoes from the adventitia region interfere. To be able to minimise the size of the region-of-interest in the radial direction, we suggest that the radial movement of the arterial vessel is first measured and that the radial movement is used as a priori information when the longitudinal movement is measured. The mean difference between the two methods is 8 and 2 standard deviation is 24 μm

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

radial arterial wall movement measurement
echo interference
adventitia
longitudinal arterial wall movement measurement
high-resolution ultrasonic method
cardiac cycle
common carotid artery
2D arterial wall movement measurement
intima-media complex

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Cinthio, Magnus
Ahlgren, A
Jansson, Tomas
Persson, Hans W
Lindström, Kjell
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
Proceedings of t ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy