SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lindgren Arne)
 

Sökning: WFRF:(Lindgren Arne) > (2000-2004) > Assessment of regio...

Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques

Wirestam, Ronnie (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Knutsson, Linda (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,MR Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
Ostergaard, Leif (författare)
visa fler...
Bolling, Max (författare)
Aunola, Juha-Petri (författare)
Lindgren, Arne (författare)
Lund University,Lunds universitet,Neurologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Geijer, Bo (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Holtås, Stig (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ståhlberg, Freddy (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medicinsk strålningsfysik, Lund,Institutionen för kliniska vetenskaper, Lund,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Medical Radiation Physics, Lund,Department of Clinical Sciences, Lund
visa färre...
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Magnetic Resonance in Medicine. - 1522-2594. ; 43:5, s. 691-700
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Regional cerebral blood flow (rCBF) was assessed using dynamic susceptibility-contrast MRI at 1.5 T. A simultaneous dual FLASH pulse sequence and Gd-DTPA-BMA (0.3 mmol/kg b.w.) were used for examination of 43 volunteers, measuring rCBF in frontal white matter (WM) and in gray matter in the thalamus (GM). Arterial input functions (AIFs) were registered 1) in the carotid artery and 2) in an artery within the GM/WM slice. The measured concentration-vs. -time curve was deconvolved with the AIF using both Fourier Transform (FT) and Singular Value Decomposition (SVD). Relative rCBF was given by the height of the deconvolved response curve. For each volunteer, eight different rCBF maps were calculated, representing different combinations of deconvolution techniques, AIFs, and filters. The average GM-WM rCBF ratios ranged from 2.0-2.2, depending on methodology. Absolute rCBF was 68 +/- 28 ml/(min 100 g) in GM and 35 +/- 13 ml/(min 100g) in WM (mean +/- SD, n = 39). GM-WM rCBF ratios obtained using SVD were 6-10% higher than corresponding ratios obtained using FT.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

cerebral blood flow (CBF)
dynamic susceptibility-contrast magnetic resonance imaging (MRI)
nonparametric deconvolution
arterial input function

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy