SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:5fb6e029-ebc9-4236-90b4-2a1bcf7d8b17"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:5fb6e029-ebc9-4236-90b4-2a1bcf7d8b17" > Eighty-peak kilovol...

  • Geijer, FredrikLund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups (författare)

Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients.

  • Artikel/kapitelEngelska2006

Förlag, utgivningsår, omfång ...

  • 2006-01-27
  • Springer Science and Business Media LLC,2006

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:5fb6e029-ebc9-4236-90b4-2a1bcf7d8b17
  • https://lup.lub.lu.se/record/153724URI
  • https://doi.org/10.1007/s00330-005-0117-xDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • The aim of this study was to assess the feasibility of minimising contrast-medium (CM) doses using 80-peak kilovoltage (kVp) 16-channel multidetector computed tomography (MDCT) with CM dose tailored to body weight, when diagnosing pulmonary embolism (PE) in azotaemic patients. Twenty-nine patients (68–93 years; 38–79 kg) with an estimated glomerular filtration rate of 12–49 ml/min underwent 80 kVp MDCT at a median dose of 200 mg iodine (I)/kg and 15 s injection time. Pulmonary artery (PA) enhancement where compared with our own reference material using 320 mg I/kg at 120 kVp and with reported figures in the literature at 120–140 kVp and a 42 g iodine CM dose. Median (1st and 3rd quartiles) values regarding CM dose were 12.2 (9.9–12.8) g iodine; density of left main and lower lobe segmental PA 339 (275–395) Hounsfield units (HU) and 354 (321–442) HU, respectively. Those enhancement values were similar to those obtained from the reference population at 120 kVp and those reported in the literature at 120–140 kVp. One patient had a transient increase in plasma creatinine. Three months’ follow-up revealed deep venous thrombosis among 1/18 patients with negative results from computed tomography (CT). We conclude that 80 kVp 16-channel MDCT to diagnose PE in azotaemic patients may be performed with markedly reduced CM doses, implying a lesser risk for CM-induced nephropathy.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Nyman, Ulf (författare)
  • Diagnostisk radiologi, MalmöForskargrupper vid Lunds universitet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:European Radiology: Springer Science and Business Media LLC16:Jan 27, s. 1165-11760938-79941432-1084

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Geijer, Fredrik
Nyman, Ulf
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
European Radiolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy