A human observer study for evaluation and optimization of reconstruction methods in breast tomosynthesis using clinical cases

Förnvik, Daniel (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Jerebko, Anna (författare)
Timberg, Pontus (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Medicinsk strålningsfysik, Malmö,Radiology Diagnostics, Malmö,Lund University Research Groups,Medical Radiation Physics, Malmö
visa fler...
Schasiepen, Ingo (författare)
Hofmann, Carina (författare)
Zackrisson, Sophia (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Andersson, Ingvar (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Mertelmeier, Thomas (författare)
Tingberg, Anders (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
SPIE, 2011
2011
Engelska.
Ingår i: Medical Imaging 2011: Physics of Medical Imaging. - : SPIE. - 0277-786X .- 1996-756X. ; 7961, s. 79615-79615
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • In breast tomosynthesis1 (BT) a number of 2D projection images are acquired from different angles along a limited arc. The imaged breast volume is reconstructed from the projection images, providing 3D information. The purpose of the study was to investigate and optimize different reconstruction methods for BT in terms of image quality using human observers viewing clinical cases. Sixty-six cases with suspected masses and calcifications were collected from 55 patients. Four different reconstructions of each image set were evaluated by four observers (two experienced radiologists, two experienced medical physicists): filtered back projection (FBP), iterative adapted FBP (iFBP) and two ML-convex iterative algorithm (MLCI) reconstructions (8 and 10 iterations) that differed in noise level and contrast of clinical details. Representation of masses and microcalcifications was evaluated. The structures were rated according to the overall appearance in a rank-order study. The differently reconstructed images of the same structure were displayed side by side in random order. The observers were forced to rank the order of the different reconstructed images and their proportions at each rank were scored. The results suggest that even though the FBP contains most noise its reconstructions are considered best overall, followed by iFBP, which contains least noise. In both FBP and iFBP methods the sharp borders and mass speculations were better represented than in iterative reconstructions while out-of-plane artifacts were better suppressed in the latter. However, in clinical practice the differences between the reconstructions may be considered negligible.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

breast tomosynthesis
iterative reconstruction
filtered back
projection
human observer study

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy